
FZR 2003-E
18
EN
Operating instructions
The voltage fl uctuations caused by this machine during start-up may during unfavourable
mains conditions cause interference with other devices connected to the same circuit. In
such a case take appropriate measures (e.g. connect the lawnmower to a different circuit or
operate it in circuit with a lower impedance).
Pay attention to necessary extension cables.
If you are not using the product, or if you know that you will not be using it soon, turn it off and
disconnect the power cable from the wall socket. Prior to cleaning, proceed in the same
manner.
Always pull the power plug from the mains, if:
you are leaving the lawnmower,
t
the machine starts to vibrate unusually (inspect immediately).
t
Electrical safety
The lawnmower can be inserted into any light power socket (with an alternating current
of 230 V). Permissible is, however, only a socket protected by a 10 A protective switch and a
protective switch against false current with max. 30 mA.
Use only undamaged power cables. The cables cannot be of any length (max. 50 m),
otherwise the power of the electrical motor will be reduced. The power cable to the machine
mus
t have a cross section of 3 × 1.5 mm2. The insulation on electric lawnmower cables is
very often damaged.
The causes of this are:
damaged caused by driving over the cable
t
compression of the cable when it goes under doors, windows, etc.
t
cracks caused by the ageing of the insulation
t
broken places caused by unprofessional connections or cable routes.
t
Cables damaged in this way are often used despite the fact that they are deadly. Cables,
power plugs and power sockets must meet the following conditions. Electrical cables for
connecting the lawnmower must have rubber insulation.
Electrical cables must be at least type H05RN-F, with 3 conductors The cable must be marked
with a print. So buy only cables labelled with a print. Power plugs and connecting sockets
on electrical cables must be from rubber and protected against spraying water. The cables
must not be of any length. Longer cables require a larger cross section. Regularly inspect
the power and connecting cables for damage. During an inspection power cables must be
disconnected. Fully unwind the power cable. Also inspect broken places on the connecting
cables at the power plug and the connecting power sockets.
The connecting power socket on connecting elements must be made from rubber, soft PVC
or another thermoplastic material of the same strength, or must be coated with this material.
Содержание FZR 2003-E
Страница 1: ...FZR 2003 E...
Страница 2: ...FZR 2003 E 2 English 9 e tina 25 Sloven ina 41 Magyarul 57 Polski 73 91...
Страница 3: ...3...
Страница 4: ...FZR 2003 E 4...
Страница 5: ...5...
Страница 6: ...FZR 2003 E 6...
Страница 7: ...7 max 15 17...