background image

Phone: 252.522.3031 • Fax: 252.522.0214

www.fieldcontrols.com

© Field Controls, LLC  

P/N 46453400 Rev F 08/09

The health aspects associated with the use of these products and their ability to aid in disinfecting of environmental air 
have not been investigated by UL.

LIMITED WARRANTY

Field Controls, LLC (“Company”) warrants that its products shall be free from defects in material and workmanship 

under normal use for the limited period indicated, 

from the date of manufacture, subject to the provisions 1-8 below.

 

 

Eighteen (18) months

 

All Field Controls Products (except for those listed below as 5 years or 90 days).

 

 

Five (5) years

 

Field Controls Direct Vent Systems (FDVS), Field Oil Vent Kits (FOVP), and ComboVents (CV).

Field Controls warrants that the products listed below shall be free from defects in material and workmanship under 

normal use for the limited period indicated, 

from the date of purchase by the consumer, subject to the provisions 

1-8 below.

 

Ninety (90) days

 

UV lamps/bulbs

 

Provisions:

1. During the limited warranty period, Company, or its authorized service representative, will repair or replace, at Company’s  

  option, without charge, a defective Product.  Product that is repaired may be repaired with new or refurbished replacement  

  parts. Product that is replaced may be replaced with a new or refurbished product of the same or similar design. Company 

  will return repaired or replacement Product to customer in working condition. Labor charges are not covered as part of the  

  limited warranty.
2. With regard to UV lamps/bulbs, customer shall be required to include a "valid proof of purchase" (sales receipt) identifying  

  the Product purchased (Product model or accurate date code information) and the date the Product(s) was purchased. 
3. Product whose warranty/quality stickers, Product serial number plates or electronic serial numbers have been removed,   

  altered or rendered illegible shall not be covered under the limited warranty. 
4. Defective Product must be returned to Company, postage prepaid.
5. IN NO EVENT SHALL COMPANY BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR SIMILAR  

  DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOST PROFITS OR REVENUE, INABILITY TO USE PRODUCT, OR OTHER  

  ASSOCIATED EQUIPMENT, THE COST OF SUBSTITUTE EQUIPMENT, AND CLAIMS BY THIRD PARTIES) RESULTING FROM  

  THE USE OF PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the  

  above limitation or exclusion may not apply to you. 
6. THIS WARRANTY AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, REMEDIES AND  

 

  CONDITIONS, WHETHER ORAL, WRITTEN, EXPRESS, STATUTORY OR IMPLIED.  TO THE EXTENT PERMITTED BY LAW,  

  COMPANY DISCLAIMS ALL IMPLIED AND STATUTORY WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY  

  AND FITNESS FOR A PARTICULAR PURPOSE.  
7. Company makes no warranty of any kind in regard to other manufacturer’s products distributed by Company. Company will  

  pass on all warranties made by the manufacturer and where possible, will expedite the claim on behalf of the customer, but  

  ultimately, responsibility for disposition of the warranty claim lies with the manufacturer.
8. Product that has been subjected to misuse, accident, shipping or other physical damage, improper installation or application,  

  abnormal operation or handling, neglect, fire, water or other liquid intrusion are not covered by the warranty.

Содержание UV-AIRE UV-12C

Страница 1: ...unting bracket 1 Flat mounting bracket 1 Duct board mounting bracket 1 Ultra Violet Lamp 1 Instruction Sheet 1 Wing nut Caution Labels Gasket WARNING DO NOT mount this unit outdoors This product is designed for indoor installation only i e attics crawl spaces basements etc WARNING UV light will break down plastic materials not rated for UV exposure Examples wire insulation flex duct drain pans and...

Страница 2: ...m2 1500 UV 18HPC 14 240 0 5 60 30 190º 73 µW cm2 2000 UV 28HPC 22 240 1 1 60 30 150º 105 µW cm2 3000 The UV 12C 18C 28C 12HPC 18HPC and 28HPC units are equipped with a circuit board to monitor the operation of the UV lamp it indicates the operation of the lamp through an LED indicator light mounted on the cover of the unit The circuit board indicates good operation of the lamp by a continuous GREE...

Страница 3: ... from the air filter For optimum cleaning effect on the A coil mount the unit in the supply plenum as close as possible to the A coil See Figure 1 Minimum Length or Width UV 12 12 inches UV 18 18 inches UV 18HP 18 inches UV 28 28 inches See general information chart for minimum mounting dimensions Minimum Length or Width UV 12 12 inches UV 18 18 inches UV 18HP 18 inches UV 28 28 inches See general...

Страница 4: ...u have 2 IF YOU HAVE METAL DUCT Apply supplied wet and stick mounting template to air duct in either a vertical or horizontal position a as shown in Figure 2B Drill b 1 8 diameter mounting holes at positions indicated on template Cut out the marked openings on the template Refer to template as shown in Figure 2B c Remove the paper template from the duct d IF YOU HAVE FLEX DUCT For installations on...

Страница 5: ...ith duct tape in either a vertical or a horizontal position See Figures 2B 3 Bend tabs outward as shown in Figure 4 b Using a knife or blade cut out a rectangle opening in the duct using the mounting plate as a c template See Figure 5 Remove the cut piece of duct See Figure 6 d Bend both tabs down and through duct at first bend point See Figures 7 8 e Bend both tabs at the second bend point up or ...

Страница 6: ...l the flat bracket and secure to the unit base with the hex nuts provided See Figure 13 Angled Bracket Installation b NOTE For angled bracket mounting refer to specifications outlined by Charts A B for mounting distances in the Angled Lamp Mounting Bracket Specifications i Remove the two hex nuts and angled bracket from included bagged hardware ii Install the angled bracket and secure to the unit ...

Страница 7: ... the board See Figure 20 12 Close the cover and tighten cover screw See Figure 21 13 Plug the power cord into a standard electrical outlet 14 NOTE Seal the joints and seams of the plenum near the mounting location to reduce any direct viewing of light See Figure 1 Press the power switch to the ON position Light on switch should be 15 on indicating power Look through view port in the box cover to b...

Страница 8: ...oard allow for the automatic operation of the UV lamp when the there is a call for heating or cooling by the thermostat After the call for heat has been satisfied the UV Aire unit will operate for 45 minutes then shut off Turn off power switch on the UV Aire unit and unplug the unit before doing any wiring 1 Loosen the cover screw and open the unit cover 2 Locate terminals 1 2 on the circuit board...

Страница 9: ... selection Straight Angled Positions Exclusive 5 Position Mounting Best Good UV Aire Configurations Standard 90º Installation Flat Bracket 16 Duct Patent Pending Angled Installation Single Lamp Angled Bracket 16 Duct Diagram B SYSTEM CHECK OUT PROCEDURE Plug the UV Aire back into the power receptacle and leave the power switch in the OFF position 1 Unplug the Ballast connector from the lamp and sw...

Страница 10: ... wipe off lamp before installing Slide lamp out carefully and dispose of properly 4 NOTE UV lamps contain a small amount of mercury like a typical fluorescent lamp Check with your local waste management authority for local disposal or recycling requirements According to the EPA s Universal Waste Rule these types of lamps may be disposed of into household waste Insert the lamp through the mounting ...

Страница 11: ... replace ballast 4 REPLACEMENT PARTS LIST For replacement parts contact your local heating service company Any questions please contact Field Controls at Phone 252 522 3031 Fax 252 522 0214 Email sales fieldcontrols com NOTE UV lamps contain a small amount of mercury like a typical fluorescent lamp Check with your local waste management authority for local disposal or recycling requirements Accord...

Страница 12: ...roof of purchase sales receipt identifying the Product purchased Product model or accurate date code information and the date the Product s was purchased 3 Product whose warranty quality stickers Product serial number plates or electronic serial numbers have been removed altered or rendered illegible shall not be covered under the limited warranty 4 Defective Product must be returned to Company po...

Отзывы: