Please retain these instructions after installation.

This device 

MUST

 be installed by a qualified agency in accordance with the manufacturer's installation instructions. The definition of 

a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged 

in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the 

precautions required, and has complied with all the requirements of the authority having jurisdiction.

This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for 

use in the mitigation, treatment, or prevention of any disease or condition.

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Installation Date:

Installed By:

Phone:

UV-AIRE

® 

AIR PURIFYING SYSTEM

Model: UV-12C, 18C, 28C, 28, 12HP, 18HP, 28HP, 12HPC, 18HPC, 28HPC

*Exclusive 5 position lamp mounting feature!

ITEMS INCLUDED IN KIT:

1- UV-Aire power unit

4- Sheet metal mounting screws

1- Angled mounting bracket

1- Flat mounting bracket

1- Duct board mounting bracket

1- Ultra Violet Lamp

1- Instruction Sheet

1- Wing nut

Caution Labels

Gasket

WARNING:

 DO NOT mount this unit outdoors.

  • This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.).

WARNING:

 UV light will break down plastic materials not rated for UV exposure:

    (Examples: wire insulation, flex duct, drain pans and humidifiers)

 

• The unit must be mounted at least 30” from the above stated type of materials.

 

• If it is necessary to mount the unit in direct line of sight of these types of materials, they must be    

     shielded with aluminum foil, aluminum foil tape, or sheet metal.

SAFETY CONSIDERATIONS

WARNING:

  Never expose eyes or skin to UV-C light from any source.

  • Looking directly at the UV-C light may cause permanent eye damage or blindness. 

  • Never operate the UV-Aire Air Purifying System out of the plenum.

 

• Designed for a closed duct system. Do not mount near a return air opening

 

• All duct openings in direct line of site of the UV light must be sealed with duct tape or equivalent   

     sealing methods.

UV-C light inhibits the growth and reproduction of germs and bacteria that circulate through a home’s 

heating and air conditioning system. The treatment is a safe, silent, and proven way to make your home a 

healthier place to live.

Содержание UV-AIRE UV-12C

Страница 1: ...unting bracket 1 Flat mounting bracket 1 Duct board mounting bracket 1 Ultra Violet Lamp 1 Instruction Sheet 1 Wing nut Caution Labels Gasket WARNING DO NOT mount this unit outdoors This product is designed for indoor installation only i e attics crawl spaces basements etc WARNING UV light will break down plastic materials not rated for UV exposure Examples wire insulation flex duct drain pans and...

Страница 2: ...m2 1500 UV 18HPC 14 240 0 5 60 30 190º 73 µW cm2 2000 UV 28HPC 22 240 1 1 60 30 150º 105 µW cm2 3000 The UV 12C 18C 28C 12HPC 18HPC and 28HPC units are equipped with a circuit board to monitor the operation of the UV lamp it indicates the operation of the lamp through an LED indicator light mounted on the cover of the unit The circuit board indicates good operation of the lamp by a continuous GREE...

Страница 3: ... from the air filter For optimum cleaning effect on the A coil mount the unit in the supply plenum as close as possible to the A coil See Figure 1 Minimum Length or Width UV 12 12 inches UV 18 18 inches UV 18HP 18 inches UV 28 28 inches See general information chart for minimum mounting dimensions Minimum Length or Width UV 12 12 inches UV 18 18 inches UV 18HP 18 inches UV 28 28 inches See general...

Страница 4: ...u have 2 IF YOU HAVE METAL DUCT Apply supplied wet and stick mounting template to air duct in either a vertical or horizontal position a as shown in Figure 2B Drill b 1 8 diameter mounting holes at positions indicated on template Cut out the marked openings on the template Refer to template as shown in Figure 2B c Remove the paper template from the duct d IF YOU HAVE FLEX DUCT For installations on...

Страница 5: ...ith duct tape in either a vertical or a horizontal position See Figures 2B 3 Bend tabs outward as shown in Figure 4 b Using a knife or blade cut out a rectangle opening in the duct using the mounting plate as a c template See Figure 5 Remove the cut piece of duct See Figure 6 d Bend both tabs down and through duct at first bend point See Figures 7 8 e Bend both tabs at the second bend point up or ...

Страница 6: ...l the flat bracket and secure to the unit base with the hex nuts provided See Figure 13 Angled Bracket Installation b NOTE For angled bracket mounting refer to specifications outlined by Charts A B for mounting distances in the Angled Lamp Mounting Bracket Specifications i Remove the two hex nuts and angled bracket from included bagged hardware ii Install the angled bracket and secure to the unit ...

Страница 7: ... the board See Figure 20 12 Close the cover and tighten cover screw See Figure 21 13 Plug the power cord into a standard electrical outlet 14 NOTE Seal the joints and seams of the plenum near the mounting location to reduce any direct viewing of light See Figure 1 Press the power switch to the ON position Light on switch should be 15 on indicating power Look through view port in the box cover to b...

Страница 8: ...oard allow for the automatic operation of the UV lamp when the there is a call for heating or cooling by the thermostat After the call for heat has been satisfied the UV Aire unit will operate for 45 minutes then shut off Turn off power switch on the UV Aire unit and unplug the unit before doing any wiring 1 Loosen the cover screw and open the unit cover 2 Locate terminals 1 2 on the circuit board...

Страница 9: ... selection Straight Angled Positions Exclusive 5 Position Mounting Best Good UV Aire Configurations Standard 90º Installation Flat Bracket 16 Duct Patent Pending Angled Installation Single Lamp Angled Bracket 16 Duct Diagram B SYSTEM CHECK OUT PROCEDURE Plug the UV Aire back into the power receptacle and leave the power switch in the OFF position 1 Unplug the Ballast connector from the lamp and sw...

Страница 10: ... wipe off lamp before installing Slide lamp out carefully and dispose of properly 4 NOTE UV lamps contain a small amount of mercury like a typical fluorescent lamp Check with your local waste management authority for local disposal or recycling requirements According to the EPA s Universal Waste Rule these types of lamps may be disposed of into household waste Insert the lamp through the mounting ...

Страница 11: ... replace ballast 4 REPLACEMENT PARTS LIST For replacement parts contact your local heating service company Any questions please contact Field Controls at Phone 252 522 3031 Fax 252 522 0214 Email sales fieldcontrols com NOTE UV lamps contain a small amount of mercury like a typical fluorescent lamp Check with your local waste management authority for local disposal or recycling requirements Accord...

Страница 12: ...roof of purchase sales receipt identifying the Product purchased Product model or accurate date code information and the date the Product s was purchased 3 Product whose warranty quality stickers Product serial number plates or electronic serial numbers have been removed altered or rendered illegible shall not be covered under the limited warranty 4 Defective Product must be returned to Company po...

Отзывы: