WARNING:
Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage
or blindness.Never operate the UV-Aire
™
Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
Page 11 of 12
CLEAN-UP OF BROKEN LAMPS
(see warnings on page two of this manual)
UV lamps contain a small amount of mercury, like a typical fl uorescent lamp. DO NOT touch any of the mercury
with your bare hands.
1. While wearing disposable, non-absorbent protective gloves, carefully pick up the large pieces of glass
with your hands.
2. Vacuum the entire area with a standard household vacuum cleaner ensuring the removal of all lamp
material.
3. Dispose of the pieces of glass, the vacuum cleaner bag, and the disposable gloves in a sealed garbage bag.
4. Check with your local waste management authority for local disposal or recycling requirements.
According to the EPA's Universal Waste Rule, these types of lamps may be disposed of into household
waste.
5. Wash hands, and remove and wash clothes for added safety measures.
Replacement Part Number
46649301
11” Lamp Assy Duo
46649302
14” Lamp Assy Duo
46511200
16” Lamp Assy
46638900
24V Multi-Mount Transformer
46529500
24V Plug-in Transformer
60530005024
QT-Ballast-24V RPLC Ballast Assy DUO UV16
60530005120
QT-Ballast-120V RPLC Ballast Assy DUO UV16
730118107
Carbon, DUO-11
730118127
Carbon, DUO-14
730118147
Carbon, DUO-16
80213041110
PRO-Cell Honeycomb, DUO-11
80213041130
PRO-Cell Honeycomb, DUO-14
80213041150
PRO-Cell Honeycomb, DUO-16
P/N 46648100 09/18 Rev J
For replacement parts, contact Field Controls at:
Phone: 252-522-3031 • Fax: 252-522-0214
Email: sales@fi eldcontrols.com
REPLACEMENT PARTS LIST