4
●
Auto start
UPS is equipped with a switch configuration mode: ON UPS starts
automatically when you connect the power supply in the OFF position
requires manual switching.
Operating principle
LUPUS series UPS (hereafter shortened as UPS) will not supply power from
its battery when the mains is working normally, which means the mains goes
through UPS into the computer with stabilised voltage.
When the mains is down, UPS will switch to Inverter mode. When the mains
voltage is lower than 165Vac or higher than 275Vac, UPS will also switch to
Inverter mode, so as to effectively protect the computer from the interruption
of electricity network.
When the mains resumes to normal status, UPS will start automatically, and
the battery charger will start charging the battery as well.
The battery will be charged fully within 8 to 10 hours of charging.
Installation & use
Panel and backboard of UPS
Figure (1) Panel and backboard schematic diagram of UPS LED models
RS232
RS232
OUT
IN
For TEL/DSL/FAX/Modem
DC INPUT
Surge Protection
AC INPUT
LUPUS 500 - 700 - 1000VA
LUPUS 500
LUPUS 700 VA - 1000VA
LUPUS 1600VA
LUPUS 1600VA
Surge Protection
AC OUTPUT
1. Mains status Indicating Led
2. Power Switch
3. RJ11+RJ45 Protection Port (Protecting Fax, Modem, Network Card etc.)
4. Computer Socket (Inverter Protected Output Socket)
5. Printer Socket (Applicable for Laser Printer, Power<600W)
6. Dry Joint Communication Interface
7. Input Socket with Fuse ( With another Spare Fuse)