45
www.fi-measurement.com
c.
Instrument displays gross weight (Tare weight +
weight of material filled).
d.
A printout
37
38
is generated automatically.
e.
A signal is sent to trigger Relay1.
6.15.4 Constant Feeding Auto Printout
39
After each successful feeding transaction, a printout of that transaction will be
generated. Refer to below for printout content and description.
TIME 23:04:56
DATE 25.10.2010
NO. 1
(Note 1)
NET 234kg
(Note 2)
TARE 97kg
(Note 3)
GROSS 331kg
(Note 4)
TOTAL 234kg
(Note 5)
TIME 23:06:16
DATE 25.10.2010
NO. 2
(Note 1)
NET 236kg
(Note 2)
TARE 56kg
(Note 3)
GROSS 292kg
(Note 4)
TOTAL 470kg
(Note 5)
Notes: -
1. (In case internal function F17 auto accumulation is set to on) sequence
number (also = total number) of current feeding transaction accumulated
to memory. 1 = 1
st
, 2 = 2
nd
…etc. 0 = auto accumulation function disable.
2. Weight of material fed of this feeding transaction.
37
When F18 is set to Mode 3.
38
Whether the current transaction will be automatically accumulated to memory depends on F17
setting.
39
Number of printout copy depends on setting for internal function F18 Mode 3.
Содержание AFM18
Страница 2: ...1 www fi measurement com ...
Страница 12: ...11 www fi measurement com 3 2 Connection Points AFM18 FM18 FM18S ...
Страница 20: ...19 www fi measurement com 5 4 Internal Function Table ...
Страница 21: ...20 www fi measurement com ...
Страница 22: ...21 www fi measurement com ...
Страница 23: ...22 www fi measurement com ...
Страница 24: ...23 www fi measurement com ...
Страница 25: ...24 www fi measurement com ...
Страница 78: ...77 www fi measurement com Fidelity Measurement Co Ltd www fi measurement com e mail info fi measurement com ...