89
Appendix R: - Quick PLU Saving Commands
Quick PLU saving command format as below: -
a.
Start String
*
“asterisk” (Hex code 02A), followed by
b.
Command code as shown on below table (all commands are case sensitive), followed by
c.
Parameters listed on the below table. Always insert semicolon (;) in front of each parameter, followed by
d.
End String
#
“number sign” (Hex code 23).
Notes: -
For RS485 communication, add @xx before start string.
xx = machine ID number set in F18.
Command Description Table
Command Definition
Command Format
Parameter Description
Start
String
Command Code
(Note R1)
Parameter &
End String
Save Preset Tare to Quick
PLU
*
S1/S2/S3
QP
PSTA
;d1;d2#
d1 = Quick PLU number 0~9.
d2 = Preset Tare value. Maximum 8 digits plus
decimal.
Save Average piece weight
to Quick PLU
*
S1/S2/S3
(Note R2)
QP
AVGW
;d1;d2#
d1 = Quick PLU number 0~9
d2 = Average piece weight value. Maximum 8
digits plus decimal
Save Check WT Limits to
Quick PLU
*
S1/S2/S3
QP
CHKW
;d1;d2;d3#
d1 = Quick PLU number 0~9.
d2 = Low check limit. Maximum 8 digits plus
decimal.
d3 = Hi check limit. Maximum 8 digits plus
decimal.
Save Check QTY Limits to
Quick PLU
*
ST
QP
CHKQ
;d1;d2;d3#
d1 = Quick PLU number 0~9.
d2 = Low check limit. Maximum 8 digits.
d3 = Hi check limit. Maximum 8 digits.
Save Customer Code and
Description to Quick PLU
*
ST
QP
CCDE
;d1;d2;d3#
d1 = Quick PLU number 000~999
d2 = Customer Code. 1~18-digit (* or and # will
not be accepted). Blank = Nothing.