3.  If you see the screen above, perform the following steps to apply the software. Otherwise 

skip to step 4. 

a.  With 

Perform Initial Install or Factory Reset

 selected, press Enter. 

b.  Use the Up and Down arrow keys to select 

the system type 

Collector SA

, and press 

Enter.  

If you need help determining the system type, 

see 

Appendix C

. 

The system displays a screen with the 

message “Congratulations, your CentOS 

installation is complete.” 

c.  Click 

Reboot

 

4.  Login to the appliance using console or SSH. 

Via SSH:

 Directly attach an Ethernet cable from a client system such as a laptop to the 

Admin/eth0 port on the appliance. The default IP address is 192.168.42.11/24. Assign a 

static IP from the same subnet to the network interface on the client system and connect to 

the appliance using SSH. 

5.  Use these credentials at the login prompt: 

 

user: 

fidelis

 

 

default password: 

fidelispass

 

6.  From the command line, run: 

sudo /FSS/bin/setup

 

You will be prompted for the SU (fidelis) password. 

7.  Within Setup, select 

Network Settings

8.  Configure the network parameters for the system and each active network interface. 

 

Use the Network Configuration table you prepared earlier. 

 

When complete, return to the top menu. 

9.  When complete, select 

OK

 to leave Setup. 

10. From command line, reboot the system:  

sudo /fss/bin/shutdown.pl --user admin --reboot 

Содержание Network Collector SA Rev-1 Series

Страница 1: ...www fidelissecurity com QUICK START GUIDE Fidelis Network Collector SA Rev I Collector SA Appliances Based on HP DL360 G10 Platforms...

Страница 2: ...ions can be found at https support fidelissecurity com or through the icon in the CommandPost K2 user interface Appliance Default Passwords System Account Default Password SSH Appliance Console fideli...

Страница 3: ...3 Network switches with enough physical ports Section 4 Logical network information IP addresses hostnames Section 5 Appendix A For Fidelis Network Software version 9 0 5 and later the appliance syste...

Страница 4: ...ed pair 1 iLO IPMI Network Optional network for remote out of band server administration Appliance Switch Port Type Qty Collector SA GbE RJ45 Cat5 copper twisted pair 1 5 Appliance Logical Network Con...

Страница 5: ...es described in sections 3 and 4 begin to connect the appliances to the networks To cable the Collector SA appliance s to the switches 1 Connect Admin eth0 port to the Admin switch port 2 Connect the...

Страница 6: ...attach an Ethernet cable from a client system such as a laptop to the Admin eth0 port on the appliance The default IP address is 192 168 42 11 24 Assign a static IP from the same subnet to the networ...

Страница 7: ...ce Description optional Specify a description for example location business unit etc 5 Click Save 6 Register the Collector to CommandPost K2 Click Register and accept the End User License Agreement EU...

Страница 8: ...nd Resources Rev I Collector SA Rev I Form Factor 1U rack mount chassis SFF CPU Dual Intel Xeon Gold 6136 12 24 core 3 0 Ghz Memory 192 GB ECC DDR4 2666Mhz Storage Capacity Configuration 480GB 2x SSD...

Страница 9: ...low shows the software to apply based on the appliance SKU You can find the SKU in the following locations Note that the SKU typically starts with FSS or FNH Appliance lid UID decal see sample on righ...

Отзывы: