FibroLAN MCM1000L-LX1-2 Скачать руководство пользователя страница 20

MCM1000S/L GBE module 

 

 

21

 

16 

– Warranty Limitation 

FibroLAN  warrants  the  equipment  to  be  free  from  defects  in  material  and  workmanship,  under 
normal and proper use and in its unmodified condition for 24 months (

unless 

otherwise agreed upon

) starting on the date of delivery from FibroLAN to its distributor. 

FibroLAN’s sole obligation under this warranty shall be to furnish parts and labor for the repair or 
replacement  of  products  found  by  FibroLAN  to  be  defective  in  material  or  workmanship  during 
the warranty period. Warranty repairs will be performed at the point of manufacture.  
Following an authorized repair, the device shall be under warranty throughout its original period 
but not less than 3 months.  
Warranty shall be void in case where unauthorized attempts to repair or disassemble 
/modify the device are evident. 
You must claim repairs or replacements under this warranty only from the reseller from which you 
have  purchased  the  device,  however  you  may  refer  directly  to  FibroLAN  Ltd.  to  claim  the 
warranty  providing  reasonable  proof  that  the  reseller  ceased  operation  and/or  unreasonably 
refused to provide you with the service. In such case you provide to FibroLAN the serial number 
of the device, date purchased, full details of reseller from whom the device was purchase and a 
copy of an invoice or another proof of the purchase.

 

 

 

 

 

 

 

 

This  document  and the information contained herein are proprietary to the manufacturer 
and  are  furnished  to  the  recipient  for  use  in  operating,  maintaining  and  repairing 
manufacturer equipment. 
The  information  within  may  not  be  utilized  for  any  purpose  except  as  stated  herein,  and 
may  not  be  disclosed  to  third  parties  without  the  written  permission  from  the 
manufacturer.  The  manufacturer  reserves  the  right  to  make  changes  to  any  technical 
specifications in order to improve reliability, function and design. 
 
  This manual is applicable for Firmware revision v 2.3 and up 
 
 

                                                                                 

 

 
 
 

©COPYRIGHT 2003 

– FibroLAN Ltd. All rights reserved  

June 2011 

– Version 2.4  

Содержание MCM1000L-LX1-2

Страница 1: ...tender 1000Base SX LX to 1000Base LX User and Installation Guide Version 2 4 FibroLAN Ltd 2 Carmel St P O Box 544 Yokneam Illit 20692 ISRAEL Tel 972 4 9591717 Fax 972 4 9591718 E mail support fibrolan...

Страница 2: ...to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operat...

Страница 3: ...ooting page 18 Specifications page 19 Module default settings page 19 Warranty Limitation page 20 Thank you for purchasing the MCM1000S L GBE Module Converter Extender from FibroLAN We hope that this...

Страница 4: ...nced diagnostics Like other MetroStar modules the MCM1000S L is fully SNMP managed All MetroStar modules are hot swappable A special LED indicates that the module is well inserted in its slot and aliv...

Страница 5: ...mode 1310nm 10Km to 1000LX single mode 1550nm DFB Extender module 80Km 2 Duplex SC MA MCM1000L LX3 3 1000LX single mode 1550nmDFBTx 1550nmRx 40Km to 1000LX single mode 1550nmDFBTx 1550nmRx Extender m...

Страница 6: ...MetroStar SNMP management module MMM 01or MMM 04 for standalone MetroStar The PMM module is normally installed in slot 4 in unmanaged MetroStar System optional module When the MetroStar chassis is no...

Страница 7: ...t from port 1 S4 UP LST ON when data is not transmitted at the same time Port 2 LST lit red implies that an idle signal is sent from port 2 S3 UP LST ON when data is not transmitted at the same time M...

Страница 8: ...t lit remove the module and re insert Is problem persists troubleshoot by inserting same module in a different slot and or another module in the suspected slot Fasten both self clinching screws using...

Страница 9: ...ld you wish to perform a local test insert first in line both receive and transmit appropriate attenuators 5db should suffice CAUTION Radiation emitted from a fiber optic connector may be hazardous to...

Страница 10: ...0 2 10 40 MCM1000S LX4 9 5 19 850 0 24 1550 DFB 0 2 25 80 MCM1000L LX1 2 11 20 1310 7 20 1310 0 10 10 20 MCM1000L LX1 3 11 20 1310 5 23 1550 DFB 0 10 10 40 MCM1000L LX1 4 11 20 1310 0 24 1550 DFB 0 1...

Страница 11: ...h handshake within that time it concludes that the opposite end device is not MA enabled subsequently it bypasses its special functions and operates like a standard straight forward access device Ther...

Страница 12: ...sor a more powerful processor is used Operating System using a newer OS provides the foundation for a more flexible system with extended capabilities Features and Characteristics Linux operating syste...

Страница 13: ...to port 1 LB Loop back LST Link Segmentation Test Default DIP switches set up S1 S2 in Down position LB disabled S3 S4 in UP position LST ON Test Mode Up Down TP F O Port Setup LB LST S1 S2 S3 S4 TP...

Страница 14: ...verride the setting of the DIP switches in GSM1000 MA and the default values are established by the MMM 01 SNMP management module installed in the MetroStar system Therefore you have to setup the DIP...

Страница 15: ...ion generates an idle signal to be transmitted from MCM1000S to Network Device A turning On the Link at Network Device A This indicates that the link segment between the MCM1000S module and Network De...

Страница 16: ...te device CPE via MA It should be noted that if the F O link of port 1 of the MCM1000S L module normally connected to a switch router port has failed the SLE will cut off the TP port or F O link of th...

Страница 17: ...any SNMP management station running popular management platforms e g FibroLAN s MetroView HP OpenView SNMPc etc When the remote MA enabled devices are connected through their F O link to a remote Acce...

Страница 18: ...in manufacturer s specifications Verify that the dB loss of the fiber cable you are connecting to plus additional losses connectors losses normally 1 5dB per mated pair Splice loss 0 3db max and 3db l...

Страница 19: ...0 edition 1000Base SX 1000Base LX IEEE802 3z Conversion Method Digital Conversion Management SNMP management via MetroStar management module MMM 01 F O ports Port 2 Duplex SC S M fiber 1310 1550nm 100...

Страница 20: ...the reseller from which you have purchased the device however you may refer directly to FibroLAN Ltd to claim the warranty providing reasonable proof that the reseller ceased operation and or unreaso...

Отзывы: