GSM1010M Gigabit Converter
6
The copper port is configured to 1000Base-T with “FDX Advertising”.
The F/O ports support GBE 1000Base-SX/LX transmissions, set to FDX (Full
Duplex) mode. Note: Ensure that the remote connected F/O port is set to 1000Gbps
Full Duplex to obtain a F/O link.
The GSM1010M is equipped with a powerful link status alert and link testing mechanism -
the “
L
ink
S
egmentation
T
est “ (LST), which allows the user to determine
the behavior of the GSM1010M converter when a link failure is detected and notifies the
Network device on the integrity of the link.
The Loop-Back feature on each port (TP and F/O) simplifies troubleshooting during link
problems.
Suitable LEDs provide visual indication for Link integrity and data activity transmit or
receive) for each port. The MA LED indicates MA active:
the GSM1010M is connected to
a remote MA enabled and active device.
The GSM1010M unit has on its front panel DIP switches (LST ON/OFF, Loop-Back
ON/OFF) per port to easily perform troubleshooting and maintenance functions.
If the MA is active or the SNMP agent is operative, the DIP switches are neutralized
If the MA and SNMP agent are not operative, then the DIP switches are functional
after powering on the GSM1010M.
The device is housed in a compact and rugged metal case, providing strong free –air-
cooling for extended stable operation and reliability.
The GSM1010M series unit is suitable for desktop, shelf (with the optimal CTF- RM) or
wall-mount installation (SCH-WM kit)
The GSM1010M device is equipped with a single internal power supply (100 - 240V
universal input), or an optional -48 VDC power supply (PS48) highly overrated to
increase the system’s MTBF. A front panel LED indicates the power status.
The ETR (Extended Temperature Range) option allows usage in industrial environment.
The default parameters setting after power on are
:
1. TP/FO loop-back - Off,
2. F->T/T->F LST ON (Test Mode)
3. Downstream/Upstream SLE - Off
4. Device enabled - Yes
5. Downstream B/W - 1000Mbps
6. FEF (Far End Fault) enabled
SNMP management
The
GSM1010M
is an SNMP managed device. Management capabilities:
a.
Out-of-Band
with any terminal emulation program (RS232 port, front panel)
b. The RJ45 port in the “Management section “ (GSM1010M front panel)
allows remote management through an SNMP manager or Telnet
c.
Supported MIBs
: MIB II (RFC1213) and FibroLAN private MIBs.
d. The
GSM1010M
converters may be managed from any SNMP management
station running popular management platforms (e.g. HP OpenView, SNMPc and
FibroLAN’s MetroView in future versions).