![FibroLAN GSM1010M Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/fibrolan/gsm1010m/gsm1010m_user-and-installation-manual_2286907040.webp)
GSM1010M Gigabit Converter
40
19 - GSM1000/MA CPE Management
This section deals with managing a GSM1000/MA remote CPE, connected via fiber to
a GSM1010M Master Unit, through either the serial connection or a Telnet connection.
The GSM1000/MA main menu is reached through the ‘Remote device’ option in the
‘Link management’ menu of the GSM1010M.
Please note that in this device, P1 (port 1) refers to the SX/LX port and P2 (port 2)
refers to the LX port (the one connected to the Master unit).
The main menu
This menu contains a header with the master system’s name (GSM1010M), to which
the GSM1000/MA is connected. The main menu enables the user to display the
device’s status (1) or to enter the device’s control menu (2).
GSM1010M/MA link - remote device – GSM1000/MA
==================================================
]
1
[
Device status
]
2
[
Device control
]
0
[
Back to GSM1010M/MA menu
Figure 1
– GSM1000/MA main menu
CPE status
The CPE’s status (figure -2) contains the following information:
•
Link status (port 1 and port 2)
•
Signal detect status (port 1 and port 2)
•
Device enabled
•
LST mode (port 2 -> port 1)
•
Loop back (LB) mode (port 2)
•
The upstream BW (0 – 1000Mbps, in 10Mbps increments)
Device status:
Link SD LST LB
P1 P2 P1 P2 Enabled P2->P1 P2 Bandwidth (up)
======================================================
On On On On On On On 1000Mbps
======================================================
Description: ‘sami ben tovim’
Firmware revision: 1.3
Figure 2
– GSM1000/MA status
CPE control
The CPE’s control menu (figure - 3) provides with options to control:
•
Set the channel’s (device) description
•
Invoke the LB/LST control menu (figure - 4)
•
Set the link’s upstream BW
•
Enable/disable channel (device) option
•
Restore device’s default configuration