![Fibocom SU806-LA Скачать руководство пользователя страница 69](http://html1.mh-extra.com/html/fibocom/su806-la/su806-la_hardware-manual_2286857069.webp)
Reproduction forbidden without Fibocom Wireless Inc. written authorization - All Rights Reserved.
FIBOCOM SU806 Series Hardware Guide
Page 69 of 79
Mode
Band
Max Power (dBm)
Min Power (dBm)
Band 4
23.0±2
< -39
Band 5
23.0±2
< -39
Band 7
23.0±2
< -39
Band 12
23.0±2
< -39
Band 17
23.0±2
< -39
Band 28
23.0±2
< -39
LTE TDD
Band 40
23.0±2
< -39
Band 41
23.0±2
< -39
8.5
RF Receiver Sensitivity
The sensitivity of each frequency band of the SU806 series module is shown in the following table:
Test condition: 3.8V power supply, environment temperature 25°C. The test bandwidth of LTE sensitivity
LTE is
10M, RB configuration please refer to 3GPP standard.
Table 8-5 RF receiver sensitivity of SU806-LA
Mode
Band
Primary
Diversity
PRX+Div
3GPP
Requirement
Unit
GSM
850
-109.2
-
-
-102
dBm
900
-108.7
-
-
-102
dBm
1800
-108.5
-
-
-102
dBm
1900
-108.5
-
-
-102
dBm
WCDMA
Band 2
-110.5
-
-
-104.7
dBm
Band 4
-110
-
-
-106.7
dBm
Band 5
-110.8
-
-
-104.7
dBm
Band 8
-111.3
-
-
-103.7
dBm
LTE FDD
Band 2
-98
-
-
-94.3
dBm
Band 3
-99
-
-
-93.3
dBm
Band 4
-98.5
-
-
-96.3
dBm