background image

 

Reproduction forbidden without Fibocom Wireless Inc. written authorization - All rights reserved. 

FG360-NA Hardware Guide

 

                                                                                                                   

 

                    13/28 

2.4.3 

  IC Statement 

Industry Canada Statement 

This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the 

following two conditions: 

(1) This device may not cause interference; and 

(2) This device must accept any interference, including interference that may cause undesired 

operation of the device. 

 

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts 

de licence. L'exploitation est autorisée aux deux conditions suivantes:   

(1) l'appareil ne doit pas produire de brouillage, et   

(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est 

susceptible d'en compromettre le fonctionnement." 

 

Radiation Exposure Statement 

This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This 

equipment should be installed and operated with minimum distance 20 cm between the radiator & your 

body. 

 
Déclaration d'exposition aux radiations:

 

Cet équipement est conforme aux limites d'exposition aux rayonnements ISED établies pour un 

environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de 

distance entre la source de rayonnement et votre corps. 

 

This device is intended only for OEM integrators under the following 
conditions: (For module device use)

 

1) The antenna must be installed such that 20 cm is maintained between the antenna and users, and 

2) The transmitter module may not be co-located with any other transmitter or antenna. 

As long as 2 conditions above are met, further transmitter test will not be required. However, the 

OEM integrator is still responsible for testing their end-product for any additional compliance 

requirements required with this module installed. 

 

Cet appareil est conçu uniquement pour les intégrateurs OEM dans les 
conditions suivantes: (Pour utilisation de dispositif module)

 

Содержание FG360-NA

Страница 1: ...FG360 NA Hardware Guide Version Draft V1 0 2 Date 2021 05 06...

Страница 2: ...Reproduction forbidden without Fibocom Wireless Inc written authorization All rights reserved FG360 NA Hardware Guide 2 28 Applicability Type NO Product Model Description...

Страница 3: ...rohibited to excerpt copy any part of or the entire document or distribute the document in any form Notice The document is subject to update from time to time owing to the product version upgrade or o...

Страница 4: ...21 05 06 Section 2 1 1 update band information V1 0 1 Xu Xialin 2021 04 22 Section 2 1 1 add weight information Section 2 3 Add section 2 3 antenna configuration Section 3 1 Update pin name of Pin 193...

Страница 5: ...6 1 1 Introduction 6 2 Overview 6 2 1 Introduction 6 2 1 1 Key Features 6 2 2 Application Framework 9 2 3 Antenna Configuration 10 3 Pin Definition 16 3 1 Pin Map 16 3 1 1 Table of Pin No and Pin Name...

Страница 6: ...integrates core devices such as Baseband Memory PMU Transceiver and PA It supports 5G NR Sub6 FDD LTE TDD LTE and WCDMA long distance communication modes Supports uplink 2 2 MIMO and downlink 4 4 MIM...

Страница 7: ...ting temperature 30 75 1 Extended operating temperature 40 85 2 Storage temperature 40 85 Physical characteristics Dimension 41 mm 44mm 2 75 mm Package 430 pin LGA Weight about 12 0 g CPU ARM Cortex A...

Страница 8: ...s reserved FG360 NA Hardware Guide 8 28 Note 1 When temperature keeps in the range of 30 75 C the module can work normally Module performance meets the 3GPP specifications 2 When temperature keeps in...

Страница 9: ...s of the FG360 module Baseband RF transceiver PMU Memory Peripheral interface Main PMU ET TRX Blocks Transceiver DRF RFFE RFFE RX TX Baseband eMCP eMMC LPDDR4X BBCLK 26MHz RFCLK 26MHz Sleep CLK 32KHz...

Страница 10: ...limited to installation in fixed applications according to Part 2 1091 b 3 The separate approval is required for all other operating configurations including portable configurations with respect to P...

Страница 11: ...iance requirements are met Antenna Installation 1 The antenna must be installed such that 20 cm is maintained between the antenna and users 2 The transmitter module may not be co located with any othe...

Страница 12: ...ged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into...

Страница 13: ...posure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20 cm between the radiator your body D claration d exposition aux radiatio...

Страница 14: ...ion NOTE IMPORTANTE Dans le cas o ces conditions ne peuvent tre satisfaites par exemple pour certaines configurations d ordinateur portable ou de certaines co localisation avec un autre metteur l auto...

Страница 15: ...required regulatory information warning as show in this manual Manuel d information l utilisateur final L int grateur OEM doit tre conscient de ne pas fournir des informations l utilisateur final qua...

Страница 16: ...118 121 124 127 130 132 264 262 259 256 253 250 247 244 241 238 235 232 229 226 223 220 217 214 211 208 205 202 199 196 193 190 187 184 181 178 175 172 166 163 160 157 154 151 148 145 142 169 139 136...

Страница 17: ...0 GND 51 SDC_DATA2 52 GND 53 SDC_DATA1 54 SDC_DATA3 55 SSUSB_TXN 56 SDC_DATA0 57 VBUS_DET 58 SSUSB_TXP 59 USB_DM 60 USB_ID 61 SSUSB_RXN 62 USB_DP 63 SSUSB_RXP 64 AP_URTS1 65 GBE1_INT 66 MDC 67 PCIE_B_...

Страница 18: ...D 240 241 RESERVED 242 GND 243 RESERVED 244 245 GND 246 247 RESERVED 248 GND 249 ADC0 250 251 GND 252 ADC1 253 RESERVED 254 GND 255 NC 256 258 GND 259 RESERVED 260 GND 261 VBAT_BB 262 GND 263 264 VBAT...

Страница 19: ...LGA pin description Pin Name Pin No Type Power Domain Reset Value Pin Description Power VBAT_BB 261 263 264 PI Baseband power input VBAT_RF 84 85 86 87 88 89 PI RF power input VDD_EXT_1V8 225 PO 1 8V...

Страница 20: ...nal WAKEUP_IN 113 DI VDD_EXT_1V8 PD Module wake up input from host NET_STATUS 106 DO VDD_EXT_1V8 PD Module network status indication NET_MODE 110 DO VDD_EXT_1V8 PD Module network mode indication SLEEP...

Страница 21: ...DATA1 53 DIO SDIO_VDD PD SDC interface DATA1 signal SDC_DATA0 56 DIO SDIO_VDD PD SDC interface DATA0 signal SDC_CLK 45 DO SDIO_VDD PD SDC interface clock signal SDC_DATA2 51 DIO SDIO_VDD PD SDC interf...

Страница 22: ...plus PCIE_B_LN0_RXN 33 AIO AVDD12_PCIE PCIe B Rx0 minus PCIE_B_LN0_RXP 30 AIO AVDD12_PCIE PCIe B Rx0 plus PCIE_B_PEWAKEN 67 DI VDD_EXT_1V8 PU PCIe B wake up signal PCIE_B_PERSTN 76 DO VDD_EXT_1V8 PU P...

Страница 23: ...put signal I2S0_DI 104 DI VDD_EXT_1V8 PD I2S data input signal I2S0_BCK 101 DO VDD_EXT_1V8 PD I2S data bit clock signal I2S0_LRCK 105 DO VDD_EXT_1V8 PD I2S frame clock signal ADC ADC0 249 AI VDD_EXT_1...

Страница 24: ...T_1V8 PD Data signal for DBI C serial 3 4 wire SPI LCD For type interface II LCD is data input signal from FG360 module and connect to LCD data output signal For type interface I LCD not has this sign...

Страница 25: ...279 DO VDD_EXT_1V8 PD MT6890 GPIO used for control WIFI RESET signal or WIFI Power enable signal EINT15 212 DI VDD_EXT_1V8 PD Interrupt input signal used as WLAN_EN BT_PRI_RXD 150 DI VDD_EXT_1V8 PD WI...

Страница 26: ...220 221 222 224 226 227 228 230 232 233 234 236 238 239 242 244 245 248 250 251 254 256 257 258 260 262 266 277 284 289 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318...

Страница 27: ...28 4 Structural Specification 4 1 Product Appearance The appearance of the FG360 module product is as shown Figure 4 1 Module product appearance 4 2 Dimension of Structure The structural dimensions of...

Страница 28: ...ithout Fibocom Wireless Inc written authorization All rights reserved FG360 NA Hardware Guide 28 28 4 3 Storage Refer to FIBOCOM FG360 NA Series SMT Design Guide 4 4 Packing Refer to FIBOCOM FG360 NA...

Отзывы: