FIBERROAD FR-5A3010P Скачать руководство пользователя страница 9

User Manual

© 2022 Fiberroad Technology Co., Ltd All right reserved

Page 9 of 11

Specifications

Ethernet Interface

Model

FR-5A3010P

FR-5A3208P

RJ45 Port

8x10/100/1000Base-TX + 

2x10/100/1000Base-Tx

8x10/100/1000Base-TX

Optical Fiber Port

2x1000Base-X(SFP

SFP Slot Port

Gigabit SFP optical fiber interface, default 

matching optical modules (optional order 

single-mode / multi-mode, single fiber / dual 

fiber optical module. LC)

Twisted Pair 

Transmission

10BASE-

T: Cat3,4,5 UTP(≤100 meter)

100BASE-

TX: Cat5 or later UTP(≤100 meter)

1000BASE-

T: Cat5e or later UTP(≤100 meter)

Port Mode(Tx)

Auto-Negotiation 

Full/Half Duplex Mode

Auto MDI/MDI-X Connection

Standards

IEEE 802.3 for 10BaseT

IEEE 802.3u for 100BaseT(X) and 100BaseFX

IEEE 802.3ab for 1000BaseT(X)

IEEE 802.3z for 1000BaseSX/LX/LHX/ZX

IEEE 802.3x for flow control

IEEE 802.1p for Class of Service

IEEE802.3az Energy Efficient Ethernet

Packet Buffer Size

2Mbits

Maximum Packet 

Length

Up to 9K

MAC Address Table

4K

Transmission Mode

Store and Forward (Full Wire Speed)

Exchange Property

Delay time: < 7μs

Backplane bandwidth: 20Gbps

LED Indicator

Power

Connect-always

RJ45

LINK/ACT: Connect-always; Data exchange-twinkle

Optical Fiber 

LINK/ACT: Connect-always; Data exchange-twinkle

Physical Characteristics 

Housing

Metal 

IP Rating

IP30

Dimensions

220*108*28 mm (L*W*H)

8.7*4.25*1.10 in (L*W*H)

Installation Mode

Desktop

Weight

500g(1.10lb)

Содержание FR-5A3010P

Страница 1: ......

Страница 2: ...ut should not be able to connect to each other Using this also improves network security 3 When AI QoS is enabled on the 8 port models Port 1 4 will prioritise Video and VoIP traffic flows over others...

Страница 3: ...e letter A to A and B to B shown as below or A1 to A2 and B1 to B2 PoE Power Supply User Manual Item Specification PoE Port Port 1 to 8 IEEE802 3af at PoE Power Supply Pin Default 1 2 3 6 Optional 4 5...

Страница 4: ...s 1000Base T RJ45 Connector Pin Assignment Pin MDI Signal Definition MDIX Signal Definition 1 BI_DA BI_DB BI_DA BI_DB 3 BI_DB BI_DA 4 BI_DC BI_DD 5 BI_DC BI_DD 6 BI_DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_D...

Страница 5: ...he data transmission and the cable should be safe The Power over Ethernet system works under the standardization of the Institute of Electrical and Electronics Engineers IEEE 802 3 committee Generally...

Страница 6: ...wer to the PoE Switch Wiring Requirements Cable laying need to meet the following requirements 1 It is needed to check whether the type quantity and specification of cable match the requirement before...

Страница 7: ...h Powered Device PD in watts Allow for the maximum power and upper end of PD classification Any unspecified devices should be assumed Class 0 For example an IEEE802 3af Class 0 device may consume 9 wa...

Страница 8: ...ower supplies Take this harsh scenario for instance A switch and its power supply will be stored in a metal enclosure exposed to direct sun at a site in the northeastern United States In winter the te...

Страница 9: ...Full Half Duplex Mode Auto MDI MDI X Connection Standards IEEE 802 3 for 10BaseT IEEE 802 3u for 100BaseT X and 100BaseFX IEEE 802 3ab for 1000BaseT X IEEE 802 3z for 1000BaseSX LX LHX ZX IEEE 802 3x...

Страница 10: ...y 5 90 non condensing Storage Temperature 20 70 4 to 158 MTBF 100 819 Hours MTBF Standard Telcordia SR 332 GB 25 Cooling Fanless Passive Cooling Noise Level 0 dBA Certification Warranty Lightning Prot...

Страница 11: ...ent Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct t...

Отзывы: