Installation Preparation

Before installation, confirm that the work environment meets the installation 

requirements, including the power needs and abundant space. Whether it is close to 

the connection equipment and other equipment are prepared or not. 

1. Avoid in the sunshine, keep away from the heat fountainhead or the area wherein 

intense EMI.

2. Examine the cables and plugs that installation requirement.

3. Examine whether the cables be seemly or not (less than 100m) according to a 

reasonable scheme. 

4. Power: DC52V power input 

5. Environment: 

working temperature: 0

50

(32 to 122

℉)

Storage Temperature: -20

70

℃ (

-4 to +158

℉)

Relative humidity 5%

95% 

noncondensing

Desktop Installation

To Install a PoE Switch on a desktop or shelf, simply complete the following steps

Step 1

Attach the rubber feet to the recessed areas on the bottom of the PoE Switch.

Step 2

:    Place the PoE Switch on the desktop or shelf near an AC power source.

Step 3

:    Keep enough ventilation space between the PoE Switch and the surrounding 

objects.

Step 4

:    Connect the PoE Switch to network 802.3at/802.3af powered device(PD) and 

switch

Step 5

:    Supply Power to the PoE Switch

Wiring Requirements

Cable laying need to meet the following requirements, 

1. It is needed to check whether the type, quantity and specification of cable match 

the requirement before cable laying; 

2. It is needed to check the cable is damaged or not, factory records and quality 

assurance booklet before cable laying; 

3. The required cable specification, quantity, direction and laying position need to 

match construction requirements, and cable length depends on actual position;

4. All the cable cannot have break-down and terminal in the middle; 

5. Cables should be straight in the hallways and turning; 

6. Cable should be straight in the groove, and cannot beyond the groove in case of 

holding back the inlet and outlet holes. Cables should be banded and fixed when 

they are out of the groove;

7. User cable should be separated from the power lines. Cables, power lines and 

grounding lines cannot be overlapped and mixed when they are in the same 

groove road. When cable is too long, it cannot hold down other cable, but structure 

in the middle of alignment rack; 

8. Pigtail cannot be tied and swerved as less as possible. Swerving radius cannot be 

too small (small swerving causes terrible loss of link). Its banding should be 

moderate, not too tight, and should be separated from other cables; 

9. It should have corresponding simple signal at both sides of the cable for 

maintaining.

Содержание FR-5A3010P

Страница 1: ......

Страница 2: ...ut should not be able to connect to each other Using this also improves network security 3 When AI QoS is enabled on the 8 port models Port 1 4 will prioritise Video and VoIP traffic flows over others...

Страница 3: ...e letter A to A and B to B shown as below or A1 to A2 and B1 to B2 PoE Power Supply User Manual Item Specification PoE Port Port 1 to 8 IEEE802 3af at PoE Power Supply Pin Default 1 2 3 6 Optional 4 5...

Страница 4: ...s 1000Base T RJ45 Connector Pin Assignment Pin MDI Signal Definition MDIX Signal Definition 1 BI_DA BI_DB BI_DA BI_DB 3 BI_DB BI_DA 4 BI_DC BI_DD 5 BI_DC BI_DD 6 BI_DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_D...

Страница 5: ...he data transmission and the cable should be safe The Power over Ethernet system works under the standardization of the Institute of Electrical and Electronics Engineers IEEE 802 3 committee Generally...

Страница 6: ...wer to the PoE Switch Wiring Requirements Cable laying need to meet the following requirements 1 It is needed to check whether the type quantity and specification of cable match the requirement before...

Страница 7: ...h Powered Device PD in watts Allow for the maximum power and upper end of PD classification Any unspecified devices should be assumed Class 0 For example an IEEE802 3af Class 0 device may consume 9 wa...

Страница 8: ...ower supplies Take this harsh scenario for instance A switch and its power supply will be stored in a metal enclosure exposed to direct sun at a site in the northeastern United States In winter the te...

Страница 9: ...Full Half Duplex Mode Auto MDI MDI X Connection Standards IEEE 802 3 for 10BaseT IEEE 802 3u for 100BaseT X and 100BaseFX IEEE 802 3ab for 1000BaseT X IEEE 802 3z for 1000BaseSX LX LHX ZX IEEE 802 3x...

Страница 10: ...y 5 90 non condensing Storage Temperature 20 70 4 to 158 MTBF 100 819 Hours MTBF Standard Telcordia SR 332 GB 25 Cooling Fanless Passive Cooling Noise Level 0 dBA Certification Warranty Lightning Prot...

Страница 11: ...ent Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct t...

Отзывы: