Regulatory Information

1.1 Electronic Emission Notices

This equipment has been tested and found to comply with the FCC Part 15, Subpart B, Class A 

and protection requirements of European Emission Standard as follows: EMI Comply with FCC 

Part 15 Class A & CE Mark Approval LVD EN 62368-1 Safety UL and others by request

1.2 FCC Class a statement

This equipment generates, uses, and can radiate radio-frequency energy, and if not installed 

and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause 

interference to radio communication. It has been tested and found to comply with the limits 

for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of 

FCC rules, which are designed to provide reasonable protection against such interference 

when the equipment is operated in a commercial environment. Operation of this equipment in 

a residential area is likely to cause interference, in which case the user at his own expense will 

be required to take whatever measures may be necessary to correct the interference. 

Changes or modifications not expressly approved by the party responsible for compliance 

could void the user’s authority to operate the equipment. 

This digital apparatus does not exceed the Class A limits for radio noise emission from digital 

apparatus set out in the Radio Interference Regulation of Industry Canada.

1.3 Disclaimer

Fiberroad Technology Co., Ltd shall not be liable for damages of any kind, including, but not limited to, 
punitive, consequential or cost of cover damages, resulting from any errors in the product information or 
specifications set forth in this document and Fiberroad Technology Co., Ltd may revise this document at any 
time without notice.

1.4 Trademarks used in this manual

Fiberroad Technology and the Fiberroad logo type and mark are registered trademarks of Fiberroad
Technology Co., Ltd . Any other trademarks mentioned in this manual are acknowledged to be the property 
of the trademark owners.

Содержание FR-5A3010P

Страница 1: ......

Страница 2: ...ut should not be able to connect to each other Using this also improves network security 3 When AI QoS is enabled on the 8 port models Port 1 4 will prioritise Video and VoIP traffic flows over others...

Страница 3: ...e letter A to A and B to B shown as below or A1 to A2 and B1 to B2 PoE Power Supply User Manual Item Specification PoE Port Port 1 to 8 IEEE802 3af at PoE Power Supply Pin Default 1 2 3 6 Optional 4 5...

Страница 4: ...s 1000Base T RJ45 Connector Pin Assignment Pin MDI Signal Definition MDIX Signal Definition 1 BI_DA BI_DB BI_DA BI_DB 3 BI_DB BI_DA 4 BI_DC BI_DD 5 BI_DC BI_DD 6 BI_DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_D...

Страница 5: ...he data transmission and the cable should be safe The Power over Ethernet system works under the standardization of the Institute of Electrical and Electronics Engineers IEEE 802 3 committee Generally...

Страница 6: ...wer to the PoE Switch Wiring Requirements Cable laying need to meet the following requirements 1 It is needed to check whether the type quantity and specification of cable match the requirement before...

Страница 7: ...h Powered Device PD in watts Allow for the maximum power and upper end of PD classification Any unspecified devices should be assumed Class 0 For example an IEEE802 3af Class 0 device may consume 9 wa...

Страница 8: ...ower supplies Take this harsh scenario for instance A switch and its power supply will be stored in a metal enclosure exposed to direct sun at a site in the northeastern United States In winter the te...

Страница 9: ...Full Half Duplex Mode Auto MDI MDI X Connection Standards IEEE 802 3 for 10BaseT IEEE 802 3u for 100BaseT X and 100BaseFX IEEE 802 3ab for 1000BaseT X IEEE 802 3z for 1000BaseSX LX LHX ZX IEEE 802 3x...

Страница 10: ...y 5 90 non condensing Storage Temperature 20 70 4 to 158 MTBF 100 819 Hours MTBF Standard Telcordia SR 332 GB 25 Cooling Fanless Passive Cooling Noise Level 0 dBA Certification Warranty Lightning Prot...

Страница 11: ...ent Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct t...