background image

 

 

Warning: Ignore the warning, non-proper use of fusion splicer could lead to fatal 

and serious inju

r

y. 

 

1. The input voltage of this model of machine is definite; please do not use the voltage 

outside the scope. Please use the correct AC and DC power supply. 

2.  When  the  fusion  splicer  comes  across  the  following  failures,  please  immediately 

remove  the  AC  power  cord  from  the  power  supply  input  and  turn  off  the  fusion 

splicer,  otherwise  will  lead  to  the  incapable  of  the  repairing  and  even  will  cause 

personal injury, death and fire.

 

 

Smoke, smell, noise or heat anomal

y  

 

Broken or damaged machines

 

 

Liquid or foreign matter enters the interior of the machine 

3.

 

This  model  of  fusion  splicer  does  not  have  the  need  to  maintain  internal 

components,  dismantling  of  fusion  splicer  and  power  modules  is  prohibited;  any 

mistake in maintenance will lead to the machine beyond repair even causing bodily 

harm. 

4. The machine has strictly limitation to the power supply module used. 

5.

 

The  fusion  splicer  is  prohibited  to  be  used  under  the  environment  with  the 

inflammable  liquid  or  flammable  gas;  otherwise  will  lead  to  fire,  explosion  and 

other serious consequences. 

 

 

 

Disclaimer Clause   

The  Company  does  not  assume  any  liability  for  all  damage  caused  by  the  use 

of non original battery. 

 

 

To  avoid  possible  wrong  operation  or  insecurity,  a  valid  ground  three-hole 

socket must be used when AC/DC adaptor access to AC 220V 50HZ power. 

Содержание FL-117

Страница 1: ...Version 1 00 FL 117 Optical Fiber Fusion Splicer User Manual Price 1 58 000...

Страница 2: ...ign matter enters the interior of the machine 3 This model of fusion splicer does not have the need to maintain internal components dismantling of fusion splicer and power modules is prohibited any mi...

Страница 3: ...9 2 5 Display brightness control 9 2 6 Cover fiber protection sleeve 10 2 7 Preparation of fiber end face 10 2 8 Place fiber 12 3 Check and Maintenance 13 3 1 Cleaning V grooves 13 3 2 Cleaning Fiber...

Страница 4: ...nt by PAS technology Applicable Fiber Cable indoor and 0 25mm 0 9mm fiber SC connector option Splicing Time 9s Heat Time 30s Cleaved Length 8 16mm Fiber Image Magnification 300 200 times View Display...

Страница 5: ...lowing is the standard configurations of fusion splicer No Name Quantity 1 Fusion Splicer 1 set 2 Carrying Case 1 set 3 AC Adaptor 1 pc 4 Power cord 1 pc 5 Cooling tray 1 pc 6 Spare Electrodes 1 pair...

Страница 6: ...3 1 3 Parts Name of fusion splicer Left Keyboard Right Keyboard Power Module Key board Power switch Windshield cover Heater LCD...

Страница 7: ...um or move the cursor Turn on the help screen The optical fiber moves right Invalid Increase the parameter quantum or move the cursor To enter the menu mode To switch on the manual driver at pausing s...

Страница 8: ...tricity supply when adapter is used for electricity supply the polymer lithium ion battery is charged at the same time The lithium battery to be changed must be the model specified by the Company 2 2...

Страница 9: ...pply for the Fusion Splicer 2 3 1 Checking of battery capacity When the power module is not in the charged state press the PUSH button on the flank of the power module Then the four battery capacity i...

Страница 10: ...the charging time is dependent on the current battery capacity of the splicer 4 If the splicer is charged when it is active the charging time should be longer The user is recommended to charge the ba...

Страница 11: ...on splicer the battery level must be checked If the battery is low or the low voltage warning is given please recharge the lithium battery timely 5 Please do not charge or discharge the battery in a l...

Страница 12: ...nto fire to prevent explosion of battery 2 4 Turn on and turn off Turn on Press button on the operator panel until the LED indicator lights turn from green to red release the button When all of the mo...

Страница 13: ...ess to confirm the brightness changes and return to standby operation interface When the display brightness is moderate the capacity loss can be reduced and the endurance of the battery can be prolong...

Страница 14: ...time Notes Please use the alcohol with purity more than 99 Fiber stripping Clean 2 7 3 Aim the edge of the fiber coating layer at the 16 calibration of the cutter yardstick and put the fiber into orie...

Страница 15: ...fiber Notes The clean cross section of fiber cannot touch other things 2 8 Place fiber 2 8 1 Open shielding cover and left and right fiber clips 2 8 2 Put the good fiber end face in the V shaped groo...

Страница 16: ...tical cleaning points and maintenance checks are described below 3 1 Cleaning V grooves If contaminants are present in the V grooves proper clamping may not occur resulting in higher splice loss The V...

Страница 17: ...lly cleaned during normal operation 2 To clean the clamp chips do the following Open the wind protector Clean the surface of the chip clamp with an alcohol impregnated thin cotton swab Remove excess a...

Страница 18: ...is with an alcohol impregnated thin cotton swab Using the cotton swab start at the center of the lens and move the swab in a circular motion until you spiral out to the edge of the lens surface Remove...

Страница 19: ...he LED indicator turn from red to green release the button now the machine is turned off 2 Remove the old electrodes and Method for tearing a Loosen screw located on electrode cover b Take electrode o...

Страница 20: ...Press to adjust the value 3 After completion of calendar setting press The date and time are stored 4 Change the spare lithium battery pack Change the spare battery according to the following procedu...

Страница 21: ...Splicer 5 Power Supply Power does not turn off when pressing Press and hold the key until the LED color changes from red to green Release to shut off the machine Few splices can be made with a fully c...

Страница 22: ...pter blinks during battery recharge Atmospheric temperature is too high more than 50 degrees C or the battery pack is charged under exposure to sunlight The battery pack has a fault or has reached the...

Страница 23: ...n the arc temperature and position Step of discharge calibration In the Ready mode press to enter Splice Menu menu Then prepare and place fiber according to the method described in fiber preparation C...

Страница 24: ...ch other things D Cover the wind protector then the fiber fusion automatically starts and the splicing loss is displayed E Reinforce the fusion point 1 Transfer fiber with protection sleeve from V gro...

Страница 25: ...nal factors such as voltage instability Unauthorized disassemble or repair Consumable parts such as electrode cleaver blade carrying case of fusion splicer etc Before shipping the splicer please consu...

Страница 26: ......

Отзывы: