FiberLamp
Installation Recommendations
Page 13 of 21
Copyright 2013
5870004A3
INSTALLATIONS WITH LESS THAN 32 ILLUMINATORS
For DMX networks in installations that include under 32 units, or for installations less than 1,200
meters (3,900 feet) in length, the signal can be daisy chained in series from one unit to the next
using either Cat-5e cable or XLR cables. Figure 18 shows a typical daisy chain configuration.
The end of the DMX daisy chain must be properly terminated.
Figure 10:
Daisy chain configuration with data termination.
LARGER INSTALLATIONS OR LONG DISTANCE
Installations requiring more than 32 units or installations spanning lengths greater than 1,200
meters (3,900 feet) will need to use a splitter/amplifier to ensure that each string of thirty
FiberLamps receives sufficient signal strength.
Figure 11:
Daisy chain configuration for larger installations requiring more than thirty-two illuminators or cable length in
excess of 1200 meters (3,900 feet).