5 Wires and Cables
Structure
The subrack alarm cable is a straight-through network cable with RJ-45 connectors
(also known as crystal heads) on both ends, as shown in Figure 5-5.
Figure 5-5
Subrack Alarm Cable
Connection
Cable Connector
Connection Description
RJ-45 connector at the subrack side
Connected to the alarm interface (ALM) on the
CIOA card.
RJ-45 connector at the PDP side
PDP850A (3000064): Connects to one of the
connectors XS1 to XS4 on the PDP.
Technical Specifications
Item
Specification
Cable type
CAT-5 twisted pair
Connector type
RJ-45
Number of wires
8
Conductor diameter
AWG24
Breakdown voltage
2000 V