AN6000-17 Optical Line Terminal Equipment Hardware Description
Structure
As shown in Figure 5-4, one end of the alarm cable for the head of row cabinet is a
three-conductor D-type connector, and the other end is the three-conductor cable
led out from the connector. The brown, black and blue wires output CALL (order
wire call), NUA (non-urgent alarm) and UA (urgent alarm) signals respectively.
(1) Three-conductor D-type connector
(2) CALL, brown
(3) NUA, black
(4) UA, blue
Figure 5-4
Alarm Cable for the Head of Row Cabinet
Connection
Cable
Connector
Connection Description
Alarm cable for the
head of row cabinet
Three-conductor D-type
connector
Connects to the XP6 terminal on the
PDP850A (3000064).
Three-conductor cable
Connected to the head of row cabinet.
5.4.2
Subrack Alarm Cable
Function
The subrack alarm cable connects the subrack with the PDP, and outputs the
subrack alarms to the PDP.
Model
The model number of the subrack alarm cable is 3695095, which is applicable to the
PDP850A (3000064).
60
Version: A