background image

3 Cards

Item

Specification

10G-10km-1270nm/1330nm-SFP+ (Single-channel Single-fiber

Bidirectional Optical Module)

10G-10km-1330nm/1270nm-SFP+ (Single-channel Single-fiber

Bidirectional Optical Module)

10G-40km-1330nm/1270nm-SFP+ (Single-channel Single-fiber

Bidirectional Optical Module)

10G-40km-1270nm/1330nm-SFP+ (Single-channel Single-fiber

Bidirectional Optical Module)

Note 1:

GE Module

and

10GE Optical Module

describe the module specifications.

Function

u

Provides the uplink ports.

u

Each uplink port can be used as the network management port to connect with

a network management computer.

u

Each uplink interface can be used as a cascade interface allowing multiple

equipment sets to be cascaded to the IP network via a single IP port.

Working Principle

Figure 3-5

Working Principle of the HU8A Card

u

The conversion module provides uplink interfaces and transmits data

transparently.

u

The control module loads the card software, controls the card operation, and

manages the card.

u

The power module supplies power to each functional module of the card.

Version: A

23

Содержание AN6000-17

Страница 1: ...AN6000 17 Optical Line Terminal Equipment Hardware Description Version A Code MN000003536 FiberHome Telecommunication Technologies Co Ltd December 2018...

Страница 2: ......

Страница 3: ...ocal sales representative service representative or distributor for any help needed at the contact information shown below Fiberhome Telecommunication Technologies Co Ltd Address No 67 Guanggu Chuangy...

Страница 4: ......

Страница 5: ...nt are used for identification purposes only and are trademarks or registered trademarks of their respective holders All rights reserved No part of this document including the electronic version may b...

Страница 6: ......

Страница 7: ...Card Structure 10 3 2 Card Overview 11 3 3 Core Switch Card 12 3 3 1 HSCA 12 3 4 Uplink Card 17 3 4 1 KU1A 17 3 4 2 HU8A 21 3 5 Power Card 24 3 5 1 PIBA 24 3 6 10G EPON Service Card 25 3 6 1 EX8A 25...

Страница 8: ...r Cable 55 5 3 Protection Earth Ground Cable 56 5 3 1 PDP Protection Earth Ground Cable 57 5 3 2 Subrack Protection Earth Ground Cable 58 5 4 Alarm Cable 59 5 4 1 Alarm Cable for the Head of Row Cabin...

Страница 9: ...ers u Operation and maintenance engineers Version Information Version Version Information A Initial version Content Chapter Summary Subrack u Subrack model and specifications u Subrack structure u Fan...

Страница 10: ...ntation Document Applied to AN6000 17 Optical Line Terminal Equipment Product Description Network planning phase AN6000 17 Optical Line Terminal Equipment Quick Installation Guide Network deployment p...

Страница 11: ...2 Subrack Subrack Model and Specifications Subrack Structure Fan Unit Slot Distribution and Cards Supported Version A 3...

Страница 12: ...ication Weight of an empty subrack excluding the fan unit 14 kg Weight of an empty subrack including the fan unit 19 kg Operating Environment Item Specification Working temperature Long term 0 to 45 S...

Страница 13: ...536 W 2 HSCA 16 GM8A 2 PIBA HU8A FAN CIOA 1087 W 1332 W 1632 W 2 HSCA 16 GPOA 2 PIBA HU8A FAN CIOA 1071 W 1140 W 1296 W 2 HSCA 8 GPOA 8 GX8A 2 PIBA HU8A FAN CIOA 1095 W 1212 W 1416 W 2 2 Subrack Struc...

Страница 14: ...AN6000 17 is not designed with an anti dust screen The cabinet is used for dust prevention 2 3 Fan Unit Model The model number of the fan unit for the AN6000 17 is 405000320 Appearance Working Princip...

Страница 15: ...des the manual mode and the intelligent mode 4 In the manual mode the fan unit operates at the speed set in the network management system 4 In the intelligent mode the core switch card of the equipmen...

Страница 16: ...fan unit is operating at speed level 7 270 W 2 4 Slot Distribution and Cards Supported Slot Distribution The AN6000 17 subrack has 22 vertical slots and one horizontal slot Card Supported The slots ca...

Страница 17: ...3 Cards Card Structure Card Overview Core Switch Card Uplink Card Power Card 10G EPON Service Card GPON XG PON Service Card Other Cards Version A 9...

Страница 18: ...ifies the card Indicator LED area Contains various indicator LEDs such as the interface status indicator LED and the card operating status indicator LED Card panel Provides card related identifiers pr...

Страница 19: ...e Dimensions H W D Core switch card HSCA 392 mm 29 7 mm 230 6 mm Uplink card KU1A HU8A 392 mm 23 mm 230 6 mm Power card PIBA 98 mm 25 1 mm 255 5 mm Service card EX8A GX8A GM8A and GPOA 392 mm 23 mm 23...

Страница 20: ...e Card Name Card Number Static Power Consumption Typical Power Consumption Maximum Power Consumption Core switch card HSCA 2202093 58 W 74 W 90 W Uplink card KU1A 2202598 16 W 23 W 30 W HU8A 2202094 1...

Страница 21: ...t system SFP 1 to 4 10GE optical port Connects to the upper layer device Table 3 2 Indicator LEDs Identifier Meaning Color Status Description ACT Working indicator LED Green ON The card is working nor...

Страница 22: ...e and forward Capacity of the core switch card 960 Gbit s Supported MAC address quantity 128 k Switching time 50 ms Interface Specifications Item Specification CONSOLE port Interface type RJ 45 Interf...

Страница 23: ...wo fiber Bidirectional Optical Module 10G 10km 1310nm SFP Single channel Two fiber Bidirectional Optical Module 10G 40km 1550nm SFP Single channel Two fiber Bidirectional Optical Module 10G 80km 1550n...

Страница 24: ...s the DHCP Server Relay Snooping function Supports the IPv6 protocol Supports uplink based on the routing protocols such as OSPF QoS function Supports flow control Supports priority queues and process...

Страница 25: ...es processing protocols and providing the USB interface local commissioning serial port monitoring serial port and out of band management network port u The switch module is used for service data swit...

Страница 26: ...from the core switch card OFF The card is not powered on normally ALM Alarm indicator LED Red ON The card has an urgent alarm OFF The card has no alarms LINK1 5 Port status indicator LED Green ON The...

Страница 27: ...dule 1 25G 80km 1490nm 1570nm eSFP Single channel Single fiber Bidirectional Optical Module GE electrical module 1000M 100m SFP 1000Base T 10GE optical module 10G 0 3km 850nm SFP Single channel Two fi...

Страница 28: ...t to connect with a network management computer u Each uplink interface can be used as a cascade interface allowing multiple equipment sets to be cascaded to the IP network via a single IP port Workin...

Страница 29: ...uickly The card is receiving configuration data from the core switch card OFF The card is not powered on normally ALM Alarm indicator LED Red ON The card has an urgent alarm OFF The card has no alarms...

Страница 30: ...km 1310nm 1490nm eSFP Single channel Single fiber Bidirectional Optical Module 1 25G 40km 1490nm 1310nm eSFP Single channel Single fiber Bidirectional Optical Module 1 25G 80km 1570nm 1490nm eSFP Sing...

Страница 31: ...ifications Function u Provides the uplink ports u Each uplink port can be used as the network management port to connect with a network management computer u Each uplink interface can be used as a cas...

Страница 32: ...3 7 Interfaces Identifier Meaning Description 0 V 48 V DC power interface Inputs the 48 V DC power supply 0 V corresponds to the high potential of the DC power supply while 48 V the low potential of...

Страница 33: ...ervice ports to access 10G EPON services by working together with ONUs 3 6 1 EX8A Basic Information Card Overview describes the number and power consumption of the card Panel Description Figure 3 6 EX...

Страница 34: ...tandby cards is interrupted OFF The card is working normally LINK1 8 Register status indicator LED Green ON A remote ONU is successfully registered via the port OFF Registration of the remote ONU via...

Страница 35: ...data voice and IPTV Multicast function Supports the IGMP proxy snooping multicast and the controlled multicast QoS function Supports real time DBA Provides the selective QoS and SLA functions Mainten...

Страница 36: ...ule loads the card software controls the card operation and manages the card u The power module supplies power to each functional module of the card u The clock module provides the working clock signa...

Страница 37: ...cator LED Red ON The card has alarms or the communication between the active and standby cards is interrupted OFF The card has no alarms LINK1 8 Port status indicator LED Green ON The port is connecte...

Страница 38: ...s real time DBA Provides the selective QoS and SLA functions Maintenance and management function Supports local and remote loopback tests Supports remote upgrade of the card software Supports automati...

Страница 39: ...rfaces Identifier Meaning Description 1 to 8 GPON XG PON Combo port Connects to a remote ONU via the ODN Table 3 14 Indicator LEDs Identifier Meaning Color Status Description ACT Working indicator LED...

Страница 40: ...ed MAC address quantity 250 k Maximum split ratio 1 256 Maximum quantity of T CONTs 2048 Bandwidth allocation granularity 64 kbit s Optical fiber connector SC PC Matching Module Module Type Module Cod...

Страница 41: ...lity function Provides the FEC function Provides OAM functions Working Principle Figure 3 9 Working Principle of the GM8A Card u The interface module provides the GPON XG PON Combo ports and enables c...

Страница 42: ...ing slowly The card is being initialized Blinking quickly The card is receiving a configuration command OFF The card is not powered on ALM Alarm indicator LED Red ON The card is being reset or has ala...

Страница 43: ...including data voice and IPTV Multicast function Supports the IGMP proxy snooping multicast and the controlled multicast QoS function Supports real time DBA Provides the selective QoS and SLA functio...

Страница 44: ...oads the card software controls the card operation and manages the card u The power module supplies power to each functional module of the card u The clock module provides the working clock signal for...

Страница 45: ...onnects to an out of band network management computer ALM Alarm interface Outputs the equipment alarms to the PDP the top of the cabinet or the head of row cabinet DC1 7 Dry contact interface Connects...

Страница 46: ...provides the dry contact interface external clock interface out of band management network port and alarm interface u The control module loads the card software controls the card operation and manages...

Страница 47: ...4 Modules Mappings Between Modules and Cards PON Module Ethernet Module Version A 39...

Страница 48: ...ported 10G EPON optical module 10G 1G BASEPRX30 10 1 25G 20km 10G EPON OLT asymmetric XFP 10G 1G BASE PRX30 EX8A 10G BASE PR30 10 1 25G 20km 10G EPON OLT symmetric XFP 10G BASE PR30 EX8A GPON optical...

Страница 49: ...dule 1 25G 10km 1310nm 1490nm eSFP Single channel Single fiber Bidirectional Optical Module KU1A HU8A HSCA 1 25G 10km 1490nm 1310nm eSFP Single channel Single fiber Bidirectional Optical Module 1 25G...

Страница 50: ...HSCA 10G 20km 1330nm 1270nm SFP Single channel Single fiber Bidirectional Optical Module 10G 10km 1270nm 1330nm SFP Single channel Single fiber Bidirectional Optical Module 10G 10km 1330nm 1270nm SFP...

Страница 51: ...nm 2 dBm to 7 dBm 1577 nm 2 dBm to 5 dBm Optical fiber connector type SC PC SC PC Transmission distance 20 km 20 km Receiving sensitivity 29 78 dBm 1270 nm 28 dBm 1310 nm 29 78 dBm Overload optical p...

Страница 52: ...cal Module Item Specification Module code 10 2 5G 20km XG PON OLT SFP N1 ODN CLASS Optical module type N1 ODN CLASS Wavelength range Tx 1575 nm to 1580 nm Rx 1260 nm to 1280 nm Encapsulation mode SFP...

Страница 53: ...2 Gbit s XG PON Tx 9 95328 Gbit s Rx 2 48832 Gbit s Output optical power GPON 1490 nm 1 5 dBm to 5 dBm GPON 1490 nm 3 dBm to 7 dBm XG PON 1577 nm 1 dBm to 6 dBm XG PON 1577 nm 5 dBm to 8 dBm Optical f...

Страница 54: ...iber Bidirectional Optical Module Optical module type Single channel two fiber bidirectional optical module Operating wavelength 850 nm 1310 nm 1310 nm 1550 nm 1550 nm Encapsulation mode eSFP eSFP eSF...

Страница 55: ...dule type Single channel single fiber bidirectional optical module Operating wavelength Tx 1310 nm Rx 1490 nm Tx 1490 nm Rx 1310 nm Tx 1310 nm Rx 1490 nm Tx 1490 nm Rx 1310 nm Tx 1570 nm Rx 1490 nm Tx...

Страница 56: ...ctional Optical Module 10G 40km 1550nm SFP Single channel Two fiber Bidirectional Optical Module 10G 80km 1550nm SFP Single channel Two fiber Bidirectional Optical Module Optical module type Single ch...

Страница 57: ...Single fiber Bidirectional Optical Module Optical module type Single channel single fiber bidirectional optical module Operating wavelength Tx 1270 nm Rx 1330 nm Tx 1330 nm Rx 1270 nm Tx 1270 nm Rx 1...

Страница 58: ...km OLT CFP4 100G Ethernet Optical module type 100G Ethernet Wavelength range 1294 53 nm to 1310 19 nm Encapsulation mode CFP4 Rate 100 Gbit s Output optical power 10 5 dBm Optical fiber connector type...

Страница 59: ...es and Cables Cable Overview Power Cable Protection Earth Ground Cable Alarm Cable Fiber Jumper Network Cable Time Synchronization Cable Coaxial Clock Cable Serial Port Line Dry Contact Cable Version...

Страница 60: ...ection Earth Ground Cable 3696084 The AN6000 17 subrack Alarm Cable for the Head of Row Cabinet 3695135 PDP850A 3000064 Subrack Alarm Cable 3695095 PDP850A 3000064 Fiber Jumper SC PC type optical fibe...

Страница 61: ...d by the distance for cable connection in the project u The 16 mm2 power cable is used by default u When the cable connection distance between the head of row cabinet and the PDP is within 25 m the 16...

Страница 62: ...ne of the connectors among 48V_1 to 48V_4 in Area A active Select one of the connectors among 48V_1 to 48V_4 in Area B standby External 48 V DC power supply Do not use the bus bar and select the activ...

Страница 63: ...PDP to the subrack Model The model numbers of the DC power cables for the AN6000 17 subrack are 408000363 48 V power cable and 408000364 0 V power cable Structure As shown in Figure 5 1 the 48 V powe...

Страница 64: ...408000364 Single wire cord end terminal Connected to the 0 V output connector of the PDP M6 ring terminal Connected to the 0 V interface of the PIBA card Technical Specifications Cable Model Cable Ty...

Страница 65: ...iption Appearance 408000007 Comprises a cord end terminal at the PDP side and an M6 uninsulated ring terminal at the cabinet side with a yellow green cable between them Connection PDP Model Cable Mode...

Страница 66: ...rotection earth ground cable is used to connect the subrack and the protection earth ground terminal of the cabinet to provide ground protection for the subrack Model The model number of the subrack p...

Страница 67: ...cable Color Yellow green Maximum current 32 A Cross sectional area of the conductor 4 mm2 5 4 Alarm Cable The alarm cables include the subrack alarm cable and the alarm cable for the head of row cabin...

Страница 68: ...ductor D type connector 2 CALL brown 3 NUA black 4 UA blue Figure 5 4 Alarm Cable for the Head of Row Cabinet Connection Cable Connector Connection Description Alarm cable for the head of row cabinet...

Страница 69: ...ion Cable Connector Connection Description RJ 45 connector at the subrack side Connected to the alarm interface ALM on the CIOA card RJ 45 connector at the PDP side PDP850A 3000064 Connects to one of...

Страница 70: ...20 Structure Classification Connector LC PC type optical fiber connector SC PC type fiber connector Connection Table 5 4 Connection of the Optical Fiber Jumper Cable Connector Card Connected Interface...

Страница 71: ...equipment is mounted in a 300 mm deep cabinet it is advisable to use the 39 mm optical fiber connectors short connectors u Among the LC PC optical fiber connectors the 48 mm long and 31 mm long ones...

Страница 72: ...1 2 Orange 2 3 White green 3 4 Blue 4 5 White blue 5 6 Green 6 7 White brown 7 8 Brown 8 Connection Cable Cable Connector Card Connected Interface Connected Connection at the Opposite End Network cabl...

Страница 73: ...Breakdown voltage 2000 V 5 7 Time Synchronization Cable Function The time synchronization cable is used to connect the 1PPS TOD interface of the equipment and the external clock device Model The mode...

Страница 74: ...GND 6 422_1_P 1PPS 7 422_2_N TOD time information 8 422_2_P TOD time information 5 8 Coaxial Clock Cable Function The coaxial clock cable is used to transmit the clock signals and connect the BITS clo...

Страница 75: ...e Technical Specifications Table 5 7 Technical Specifications of the Coaxial Clock Cable Item Specification Cable type SYV 75 2 2 Connector type SAA type coaxial connector Characteristic impedance 75...

Страница 76: ...or Pin Transmitted signal of the equipment 3 2 GND 4 5 5 Received signal of the equipment 6 3 Connection Cable Cable Connector Connection Description Serial port line RJ 45 connector Connected to the...

Страница 77: ...erature fans shake door access control etc Model The model number of the dry contact cable is 3695452 Structure Connection Cable Cable Connector Connection Description Dry contact cable RJ 45 connecto...

Страница 78: ...6 Cabinet The following introduces the cabinets used by the AN6000 17 Cabinet Overview Detailed Dimensions of the Cabinet Equipment Layout 70 Version A...

Страница 79: ...When the equipment is mounted in a 300 mm deep cabinet it is advisable to use the 39 mm optical fiber connectors short connectors u Among the LC PC optical fiber connectors the 48 mm long and 31 mm l...

Страница 80: ...00 mm deep cabinet with anti dust screen 4102584 1600 600 600 79 4102583 2000 600 600 89 4102582 2200 600 600 99 4102581 2600 600 600 109 Note 1 The AN6000 17 uses the 404000070 cabinet by default In...

Страница 81: ...6 Cabinet 6 3 Equipment Layout Guide When multiple AN6000 17 subracks are to be installed in a cabinet arrange them from the top down 21 inch Cabinet Note 1 Unit mm Version A 73...

Страница 82: ...7 PDP PDP Overview PDP850A 3000064 74 Version A...

Страница 83: ...rrent of a single channel is 63 A Range of output voltage 38 V to 60 V Output channels Eight channels of output power Output current The maximum current of a single channel is 63 A 7 2 PDP850A 3000064...

Страница 84: ...Subrack alarm aggregation connector 11 Alarm cascade terminal 12 Branch power rail 48V output connector A 13 Branch power rail 0V output connector A 14 Branch power rail 0V output connector B 15 Bran...

Страница 85: ...rmation from the equipment inside the cabinet Alarm cascade terminal 11 XP1 to XP4 XP1 to XP4 correspond to XS1 to XS4 one by one When two PDPs are installed in the cabinet the alarm cables of the fro...

Страница 86: ...tead of indicating the working status of the PDP Note Pin2 and pin3 of JP1 have been shorted by default before delivery of the PDP Lightning Protection Module The lightning protection module is insert...

Страница 87: ...en do you use the documentation Frequently Rarely Never Other please specify 2 When do you use the documentation in starting up a project in installing the product in daily maintenance in trouble shoo...

Страница 88: ...inion on the Figures in the documentation Beautiful Unbeautiful your advice Practical Unpractical your advice 10 What is your opinion on the layout of the documentation Beautiful Unbeautiful your advi...

Отзывы: