AN5116-06B Optical Line Terminal Equipment
Hardware Description
Version A
Code: MN000000067
FiberHome Telecommunication Technologies Co., Ltd. January 2010
Страница 1: ...AN5116 06B Optical Line Terminal Equipment Hardware Description Version A Code MN000000067 FiberHome Telecommunication Technologies Co Ltd January 2010...
Страница 2: ......
Страница 3: ...d after sales service Please contact your local sales representative service representative or distributor for any help needed at the contact information shown below FiberhomeTelecommunication Technol...
Страница 4: ......
Страница 5: ...e used for identification purposes only and are trademarks or registered trademarks of their respective holders All rights reserved No part of this document including the electronic version may be rep...
Страница 6: ......
Страница 7: ...Introduces the overall installation and verifying procedure from unpacking inspection to power on examination after the equipment is delivered on site and provides reference information e g safety pr...
Страница 8: ...m levels possible reasons effects on the system and processing procedure to guide users on effective alarm processing AN5116 06A Optical Line Terminal Equipment Troubleshooting Guide Introduces the fa...
Страница 9: ...eaders This manual is intended for the following readers Marketing engineers Commissioning engineers Operation and maintenance engineers To utilize this manual these prerequisite skills are necessary...
Страница 10: ...plink Card CES Mode CE1B 32 E1 Optical Interface Card CES mode type B PUBA Public Card type A HSWA Core Switch Card EPON card No 2 115 334 HSWA Core Switch Card type A card No 2 115 331 HU1A 4 GE 1 10...
Страница 11: ...1 6 Ventilation Principle 1 7 2 The PDP 2 1 2 1 Function 2 2 2 2 Structure 2 2 2 3 Power Terminals 2 3 2 3 1 Power Supply Connector Posts 2 3 2 3 2 Automatic Circuit Breakers 2 4 2 4 Specifications 2...
Страница 12: ...EC4B Card 4 5 4 4 The C8B Card 4 8 4 5 The GC4B Card 4 10 4 6 The C155A Card 4 13 4 7 The CE1B Card 4 15 4 8 The HU1A Card 4 17 4 9 The HU2A Card 4 18 4 10 The GU6F Card 4 20 4 11 The PUBA Card 4 21...
Страница 13: ...of the key on the HSWA card 4 4 Figure 4 2 The location of the keys of the EC4B card 4 7 Figure 4 3 The location of the key of the C8B card 4 10 Figure 4 4 The location of the keys of the GC4B card 4...
Страница 14: ...Figure 5 14 The serial port cable 5 11 Figure 5 15 The dry contact cable 5 12 Figure 5 16 The subrack protective earth ground cable 5 13...
Страница 15: ...4B card indicator LEDs 4 6 Table 4 8 The EC4B card keys 4 6 Table 4 9 The EC4B card technical specification 4 7 Table 4 10 The C8B card interfaces 4 8 Table 4 11 The C8B card indicator LEDs 4 9 Table...
Страница 16: ...card interfaces 4 21 Table 4 36 The PUBA card indicator LEDs 4 21 Table 4 37 The PUBA card key 4 21 Table 4 38 The PUBA card technical specification 4 22 Table 5 1 Purposes of fiber jumpers 5 4 Table...
Страница 17: ...on A 1 1 1 The Cabinet This chapter introduces the AN5116 06B cabinet and includes the following contents Appearance Size and Weight Structure Typical Layout Wiring Inside the Cabinet Ventilation Prin...
Страница 18: ...of the cabinet 1 2 Size and Weight In terms of height the cabinets can be classified into 4 types Table 1 1 provides the size and weight of each type Table 1 1 The size and weight of the cabinets Size...
Страница 19: ...9 10 11 12 1 Rear door 5 Channel 9 Ventilation hole at the cabinet bottom 2 Wiring hole on the cabinet top 6 ESD protective earth ground fastener 10 Front door 3 Ventilation hole on the cabinet top 7...
Страница 20: ...olor Meaning Status Description Red Emergency ON An emergency alarm in equipment OFF No emergency alarm in equipment Yellow Non emergency ON A non emergency alarm in a card OFF No non emergency alarm...
Страница 21: ...m cables inside the cabinet can be arranged in the top access wiring or floor access wiring mode Figure 1 4 and Figure 1 5 illustrate the layouts of the wires and cables under the top access wiring mo...
Страница 22: ...AN5116 06B Optical Line Terminal Equipment Hardware Description 1 6 Version A Figure 1 5 The layout of the wires and cables in the floor access wiring mode...
Страница 23: ...Figure 1 6 A flow of air is forced by the air guide unit at the lower part of the subrack into the cabinet After being blown by the fan unit on the top of the subrack the cooling air passes upward th...
Страница 24: ......
Страница 25: ...Version A 2 1 2 The PDP This chapter introduces the AN5116 06B PDP and includes the following contents Functions Structure Power Terminals Parameter Specifications...
Страница 26: ...e power cabinet in the equipment room 2 2 Structure The hardware no of PDP is 3 000 059 The PDP is small and compact Its structural and engineering design complies with the relevant national and inter...
Страница 27: ...wer into the PDP Branch power supply connector posts Located on the left side of PDP rear panel are used to connect subrack power cables and output PDP s power rail to the subracks Caution P1 and P2 c...
Страница 28: ...ower supply connector posts and ACBs Main Power Connector Post Rear Panel Branch Power Connector Post Rear Panel ACB Front Panel 48V1 P1_ 48V1 K11 P1_ 48V2 K12 P1_ 48V3 K13 48V2 P2_ 48V1 K21 P2_ 48V2...
Страница 29: ...t specifications of PDP Table 2 2 The PDP parameter specifications Item Parameter Size 89mm 480mm 230mm Height Width Depth Voltage 48V 20 Current The summed current of main power is not greater than T...
Страница 30: ......
Страница 31: ...Version A 3 1 3 The Subrack This chapter introduces the AN5116 06B subrack and includes the following contents Structure Size and Weight Subrack Configuration Fan Unit Air Guide Unit Subrack Interface...
Страница 32: ...arious components of the subrack are illustrated in Figure 3 1 Figure 3 1 Subrack structure diagram 3 2 Size and Weight Table 3 1 shows the size and weight of the subrack Table 3 1 The size and weight...
Страница 33: ...ck configuration The AN5116 06B subrack totally has 20 vertical slots The slots 1 8 and 11 18 accommodate the following cards the EC4B the GC4B the C155A the CE1B or the PUBA The slots 9 and 10 are sl...
Страница 34: ...e no of the fan unit is 2 119 295 The AN5116 06B is provided with 3 fan units Each fan unit can be installed and removed independently Figure 3 3 illustrates the appearance of the fan unit Figure 3 3...
Страница 35: ...e unit is the air inlet for the subrack s forced air cooling During operation ensure that the air inlet on the front panel of the air inlet and cable connection unit is free from coverings so as to gu...
Страница 36: ...the subrack to supply DC power to the subrack 3 6 2 Environmental Monitoring Interface Symbol Type Quantity Purpose ESC RJ 45 1 Not used currently 3 6 3 Alarm Interface Symbol Type Quantity Purpose A...
Страница 37: ...indicator LEDs keys and technical specifications of all cards used in the AN5116 06B It includes the following contents Card Configuration Table The HSWA Card The EC4B Card The C8B Card The GC4B Card...
Страница 38: ...tical interface HU2A 2 170 854 Provides 2 GE uplink optical electrical interfaces and two 10GE uplink optical interfaces GU6F 2 170 855 Provides 6 GE uplink optical interface Public card 1 8 11 18 PUB...
Страница 39: ...e HSWA card interfaces Symbol Meaning Description Console Local Management Serial Interface Used to connect a CLI network management computer FE Local Management Ethernet Interface Used to connect an...
Страница 40: ...standby switching Key Description Table 4 4 The HSWA card key Symbol Meaning Description K1 Card reset key For resetting the card K1 The mounting side The panel side Figure 4 1 The location of the ke...
Страница 41: ...d SLA Provides FEC Supports local and remote loopback tests Provides OAM Supports automatic discovery and detection of ONUs Support pre authorization and pre configuration of ONUs Provides automatic u...
Страница 42: ...failed to establish a communication link between the active card and the standby card OFF The card is working normally LNK1 4 Port status LEDs Green ON A remote ONU is connected and authorized OFF No...
Страница 43: ...sult in interruption of all ONU services carried by the EC4B card The reset operation is generally conducted in course of the card maintenance and upgrade It is not recommended that the user directly...
Страница 44: ...oopback tests Provides OAM Supports automatic discovery and detection of ONUs Support pre authorization and pre configuration of ONUs Provides automatic upgrade of ONU software for convenient ONU main...
Страница 45: ...e software has not been started ALM Alarm indicator Red ON The card is resetting experiencing an alarm or has failed to establish a communication link between the active card and the standby card OFF...
Страница 46: ...s generally conducted in course of the card maintenance and upgrade It is not recommended that the user directly issue a reset command using the reset key Technical Specification Table 4 13 The GC8B c...
Страница 47: ...pre authorization and pre configuration of ONUs Supports remote software upgrade of the card software Interface Description Table 4 14 The GC4B card interfaces Symbol Meaning Description 1 4 GPON inte...
Страница 48: ...has not been powered on or the software has not been started ALM Alarm indicator Red ON The card is resetting experiencing an alarm or has failed to establish a communication link between the active c...
Страница 49: ...issue a reset command using the reset key Technical Specification Table 4 17 The EC4B card technical specification Item Specification Power consumption 40w 4 6 The C155A Card Main Function Provides t...
Страница 50: ...escription ACT Active LED Green ON The card is working normally Blink slowly The card is initializing Blink quickly The card is executing a configuration command OFF The card is not powered on ALM Ala...
Страница 51: ...e user directly issue a reset command using the reset key Technical Specification Table 4 21 The C155A card technical specification Item Specification Power consumption 40w 4 7 The CE1B Card Main Func...
Страница 52: ...Description Table 4 23 The CE1B card indicator LEDs Symbol Meaning Color Status Description ACT Active LED Green ON The card is working normally Blink slowly The card is initializing Blink quickly Th...
Страница 53: ...et key Technical specification Table 4 25 The CE1B card technical specification Item Specification Power consumption 40w 4 8 The HU1A Card Main Function Provides four GE uplink optical electrical inte...
Страница 54: ...d ON The card is resetting experiencing an alarm or has failed to establish a communication link between an active card and a standby card OFF The card is working normally LNK1 5 Port status LEDs Gree...
Страница 55: ...tive LED Green ON The card is working normally Blink slowly The card is initializing Blink quickly The card is executing a configuration command OFF The card is not powered on ALM Alarm Indicator Red...
Страница 56: ...k optical electrical interface Provides GE uplink optical electrical interface and connect with the IP network Indicator LED Description Table 4 33 The GU6F card indicator LEDs ID Meaning Color Status...
Страница 57: ...n Table 4 36 The PUBA card indicator LEDs ID Meaning Color Status Description ACT Active LED Green ON The card is working normally Blink slowly The card is initializing Blink quickly The card is execu...
Страница 58: ...ult in interruption of all services carried by the PUBA card The reset operation is generally conducted in course of the card maintenance and upgrade It is not recommended that the user directly issue...
Страница 59: ...his chapter introduces the AN5116 06B various cables and connectors and includes the following contents Power Cable Fiber Jumper E1 CABLE Clock Cable Coaxial Network Cable Serial Port Cable Dry Contac...
Страница 60: ...omposed of three cables each with a unique color The blue power cable is a DC 48V power cable The hardware no is WKE3 696 097 Its appearance is shown in Figure 5 1 Figure 5 1 The DC 48V power cable Th...
Страница 61: ...the AN5116 06B is used to connect the PDP and the subracks and provide both the active and standby power supplies for the subracks The hardware no is WKE3 696 229 The subrack power cables have already...
Страница 62: ...The fiber jumper is used to connect the optical interface of the card and the ODF The purpose of the fiber jumper varies depending on the interface type as shown in Table 5 1 Table 5 1 Purposes of fi...
Страница 63: ...own in Table 5 2 Table 5 2 The corresponding relationship between the card and the fiber jumper Card Interface Fiber Jumper C155A 1 2 LC PC EC4B 1 4 SC PC GC4B 1 4 SC PC HU1A XFP SFP LC PC HU2A XG GE...
Страница 64: ...cable Terminal Definition The end of the E1 cable connected with the CE1B card is DB 44P type plug and the end connected with the MDF is composed of bare wires Figure 5 10 illustrates the appearance...
Страница 65: ...14 th E1 Tx 3 18 13 7 th E1 Rx 3 18 13 15 th E1 Rx 2 17 14 7 th E1 Tx 2 17 14 15 th E1 Tx 1 16 15 8 th E1 Rx 1 16 15 16 th E1 Rx 31 32 16 8 th E1 Tx 31 32 16 16 th E1 Tx 17 24 15 30 1 17th E1 Rx 25 32...
Страница 66: ...erfaces of the AN5116 06B C155A and CE1B cards with the MDF in the equipment room Appearance View The hardware no of the coaxial clock cable is 3 695 187 Its appearance is illustrated in Figure 5 11 F...
Страница 67: ...SFP GE Connects the IP network and implements an uplink interface Connects an ANM2000 computer that implements network management monitor The AN5116 06B can automatically identify a straight through...
Страница 68: ...e 5 5 The wiring scheme of the straight through network cable Pin of the Local End Wire Color Pin of the Opposite End 1 White orange 1 2 Orange 2 3 White green 3 4 Blue 4 5 White blue 5 6 Green 6 7 Wh...
Страница 69: ...s 3 695 341 Its appearance is illustrated in Figure 5 14 Figure 5 14 The serial port cable Terminal Definition The end of serial port cable connected with the AN5116 06B is a RJ 45 connector and the e...
Страница 70: ...humidity temperature fan vibration and access control Appearance View The hardware no of the dry contact cable is 3 695 452 Its appearance is shown in Figure 5 15 Figure 5 15 The dry contact cable Ter...
Страница 71: ...tact device level output end 6 Green Dry contact device level output end 7 White brown Dry contact device level output end 8 Brown Dry contact device level output end 5 8 Subrack Ground Cable Purpose...
Страница 72: ......
Страница 73: ...tical Network FE Fast Ethernet GE Gigabit Ethernet IP Internet Protocol LAN Local Area Network MGCP Media Gateway Control Protocol NGN Next Generation Network ONU Optical Network Unit PDP Power Distri...
Страница 74: ......
Страница 75: ...eneral Please give your advice on the items listed below about this manual by the symbol Adjust its structure Contents more detailed Give more examples Expression more concise Add more illustrations O...
Страница 76: ......