background image

 

 

16 

 

 

b. 

Outgoing

 connections are made from the APU to external monitoring equipment. 

This is used for integration with Fiber SenSys FiberCommander. 

i.  set the 

Active Connect

 menu is set to 

Auto Start

 

ii.  In  the 

Endpoint  Configuration

  section  of  the 

Connection  Settings

 

screen,  verify  or  enter  the  correct  information,  according  to  the following 
formats and uses: 
 
Local Port 

 

10001   

 

incoming

 or 

outgoing 

 

Remote Host  XXX.XXX.X.XXX 

 

outgoing

 

Remote Port  10000   

 

 

outgoing to FiberCommander 

 
The Remote Host entry should contain the IP address for the monitoring 
equipment, such as the PC running FiberCommander. 

 

Figure 18:

 Settings for an 

Outgoing

 Connection 

 

 

2. 

Click  on  the 

OK

  button  to  enter  the  changes.  The 

Done!

  notation  again  appears 

next to the 

OK

 button to indicate that the changes have been accepted.

 

Содержание Fiber Defender FD348R

Страница 1: ...AN ESW 006 APU Networking Rev G Confidential Limited Distribution Application Note APU Networking...

Страница 2: ...any kind with regard to the documentation provided herein Fiber SenSys Inc reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation...

Страница 3: ...ant to assign or you prefer to use a dynamically assigned IP address DHCP 8 If you know the IP address that you want to assign 8 Configuring the Network Settings 9 Appendix A Identifying the Network P...

Страница 4: ...o has an operating knowledge of the network administration and the network where the APU is being installed After reading this document you should be able to 1 Determine if a particular APU supports n...

Страница 5: ...location of the Ethernet RJ 45 jack varies by APU model The jack may be labeled TCP IP or Ethernet Port CAUTION Some APU models support accessories that are also connected using RJ 45 jacks If the inc...

Страница 6: ...t configure the APU s network settings To do this you will need the following A PC connected to the same physical network as the APU The setup program for the Lantronix DeviceInstaller software The se...

Страница 7: ...r 1 Launch DeviceInstaller on the PC on which it was installed 2 Once the DeviceInstaller software is running press the Search button 3 Wait briefly for the program to search out devices and observe t...

Страница 8: ...ing the Network Settings section The automatically assigned IP address should be visible the next time that you press Search on the main DeviceInstaller window NOTE Some monitoring software expects ma...

Страница 9: ...has completed press Finish button to exit the wizard Note If you encounter a problem during the assignment the APU may have become disconnected from the physical network In this situation you should...

Страница 10: ...tering the APUs IP address into the browser 3 Press the Enter key A login screen will appear as shown on the following page Figure 9 XPort device login screen 4 Leave the User name and Password fields...

Страница 11: ...pment can be designed for either incoming or outgoing connections You must contact the vendor of the monitoring equipment for details 6 For incoming connections set the values as follows a Accept Inco...

Страница 12: ...played again 10 Serial and network settings are complete Close the browser window The APU is now ready for network operation If you have any problems or questions with the process of setting the APU u...

Страница 13: ...ify the exact location of the jack CAUTION For APU models that provide support for accessory modules it is important to use the proper jack for the network port because the APU may not operate correct...

Страница 14: ...t up The web page for such devices looks like this Figure 15 XPort Device Server Configuration Manager home screen The following steps describe how to configure the settings on devices with the older...

Страница 15: ...were applied Connection Settings 1 From the main menu in the left hand panel select Channel 1 Connection The Connection Settings screen displays The details of what is displayed depends on whether the...

Страница 16: ...rect information according to the following formats and uses Local Port 10001 incoming or outgoing Remote Host XXX XXX X XXX outgoing Remote Port 10000 outgoing to FiberCommander The Remote Host entry...

Страница 17: ...Level are set as shown above to ensure proper communication with the APU a CP 1 direction is set to Output b CP 1 Active Level is set to High Apply the New Settings 1 In order to apply and save all c...

Страница 18: ...Close the browser window The APU is now named and ready for network operation 5 Configure the monitoring equipment software using the instructions provided by the manufacturer If you have any problems...

Страница 19: ...er Fiber SenSys reserves the right to modify and adjust the protocol itself over time However the rest of this section provides information that can be useful in constructing software that attempts to...

Страница 20: ...mplement a specific behavorial state machine for communication A flowchart roughly describing the state machine is displayed below Later subsections will describe the communication states in more deta...

Страница 21: ...platform status report PSR every 20 seconds and a ping response every 130 seconds in order for the system to identify the APU and to determine whether to communicate with it When a ping request is re...

Страница 22: ...ation is set to a maximum of 31 characters The ping in should be received by the APU within every 130 seconds or the handshake process is diverted back to the beginning where the system waits for the...

Страница 23: ...en any type of event occurs an ID field index ID SZ0001 ID is updated This ID field acts as an event counter Figure 25 Intrusion message The DetectionEvent field displays the value Intrusion indicatin...

Страница 24: ...24 Figure 26 Fault message...

Страница 25: ...urred an intrusion can no longer be detected by the device The DeviceState field indicates Fault and the CommunicationState field shows the communication status as Fail When the fault condition is rep...

Страница 26: ...connected to a tamper switch either directly or through a Fiber SenSys accessory device such as the OM525 a tamper alarm is signaled when the switch opens This condition is indicated by DeviceState a...

Страница 27: ...us report Events alarms and faults affect the status of the APU Whenever the device state changes a platform status report or PSR is immediately sent to notify the system and users F Figure 29 Platfor...

Страница 28: ...007 10 08T15 12 24 000 UpdateTime the time with time zone that the change of state occurred APU configuration parameters Some APU configuration parameters can be changed via XML communication For exam...

Страница 29: ...one of the settings is out of range or a parameter name is invalid the APU responds with a Device Configuration message that includes the heading DeviceConfiguration MessageType Response RequestID X...

Страница 30: ...e For example suppose a system has one hyperzone HZONE 1 which contains two zones ZONE 1 and ZONE 2 and ZONE 1 is moved to a newly created hyperzone HZONE 2 A PSR is sent to notify the system of the c...

Страница 31: ...31 Figure 33 PSR indicating a zone move part 3 Figure 32 PSR indicating a zone move part 2...

Отзывы: