29
confIguratIon
61.
Power reports – on change
Description
This parameter defines minimal change (from
the last reported) in measured power that re-
sults in sending new report. For loads under
50W the parameter is irrelevant, report are sent
every 5W change.
Parameter size
2B
Default value
15 (15%)
Available
values
0 - reporting on change disabled
1-500 (1-500%, 1% step) – minimal change
62.
Power reports – periodic
Description
This parameter defines reporting interval for
measured power. Periodic reports are indepen-
dent from changes in value (parameter 61).
Parameter size
2B
Default value
3600 (1h)
Available
values
0 – periodic reports disabled
30-32400 (30s-9h, 1s step) – time interval
65.
Energy reports – on change
Description
This parameter defines minimal change (from
the last reported) in measured energy that re-
sults in sending new report.
Parameter size
2B
Default value
10 (0.1kWh)
Available
values
0 - reporting on change disabled
1-500 (0.01-5kWh, 0.01kWh step) – minimal
change
66.
Energy reports – periodic
Description
This parameter defines reporting interval for
measured energy. Periodic reports are indepen-
dent from changes in value (parameter 65).
Parameter size
2B
Default value
3600 (1h)
Available
values
0 – periodic reports disabled
30-32400 (30s-9h, 1s step) – time interval