22

confIguratIon

Switch Multilevel commands sent to association groups for pa-

rameter 151 set to 2

Click

Hold

Release

Button 1 

and 2

Start/Stop Level 

Change: 2nd 

group

Set Level: 3rd 

group

Содержание WALLI FGWREU-111

Страница 1: ...OPERATING MANUAL EN v1 0 FIBARO WALLI ROLLER SHUTTER FGWREU 111...

Страница 2: ......

Страница 3: ...g the device 10 5 Adding to Z Wave network 11 5 1 Adding manually 11 5 2 Adding using SmartStart 12 6 Removing from Z Wave network 13 7 Calibration 14 8 Operating the device 16 8 1 Controls 16 8 2 But...

Страница 4: ...g changes into the configuration of connections or the load must be always performed with disabled fuse To avoid risk of electrical shock do not operate the device with wet or moist hands Do not modif...

Страница 5: ...covers or covers from the following prod uct lines see Parts compatibility on page 36 GIRA System 55 Standard 55 E2 Event Event Clear Legrand C liane Schneider Odace Active power and energy metering S...

Страница 6: ...mmended wires cross section area between 1 5 4 0mm2 stripped 11 5 13mm of insulation Operating temperature 0 35 C Ambient humidity 10 95 RH without condensation Radio protocol Z Wave 500 series chip R...

Страница 7: ...dards and with depth no less than 40mm Do not connect devices which are not compliant with the specifi cation or relevant safety standards Do not connect heating devices Do not connect SELV or PELV ci...

Страница 8: ...nstalling with Legrand or Schneider covers 1 Pull out the original switch button 2 Take off the original cover plate 3 Dismount the original mounting frame 4 Snap the new mounting frame Additional mou...

Страница 9: ...arameter 13 to 0 When installing with FIBARO covers 1 Insert the device with mounting frame into the mounting box and secure with mounting claws and screws 2 Snap the cover plate to the device 3 Snap...

Страница 10: ...the new switch button to the device When installing with Schneider covers 1 Insert the device with mounting frame into the mounting box and secure with mounting claws and screws 2 Snap the new cover p...

Страница 11: ...add mode see the controller s manual 3 Quickly three times click one of the buttons 4 If you are adding in Security S2 Authenticated scan the DSK QR code or input the underlined part of the DSK label...

Страница 12: ...Security S2 Authenticated add mode see the controller s manual 2 Scan the DSK QR code or input the underlined part of the DSK label on the bottom of the box 3 Power the device 4 Wait for the adding p...

Страница 13: ...in resetting the device to factory defaults To remove the device from the Z Wave network 1 Power the device 2 Set the main controller into remove mode see the controller s manual 3 Quickly three time...

Страница 14: ...cess completing full cycle up down and up again During the calibration the LED frame blinks white 6 Test whether the positioning works correctly Automatic positioning of standard roller blind using th...

Страница 15: ...set to 6000 60 seconds in parameters 156 and 157 3 Move roller blinds between extreme positions by clicking or switch If roller blind stops before reaching top increase value of pa rameter 156 If rol...

Страница 16: ...ate slats rotation up Hold initiate slats rotation down Release to stop the movement Other actions Perform following actions on one of the buttons to 3xClick start learn mode to add remove to from Z W...

Страница 17: ...ticated Blinking red entering the menu not added to a Z Wave network White start calibration Green reset energy consumption memory Magenta start range test Yellow reset to factory defaults 8 4 Menu Me...

Страница 18: ...etting the device is not the recommended way of removing the device from the Z Wave network Use re set procedure only if the primary controller is missing or inoperable Certain device removal can be a...

Страница 19: ...energy consumed by a device through a time pe riod Consumers of electricity in households are billed by suppli ers on the basis of active power used in given unit of time Most commonly measured in ki...

Страница 20: ...ugh other modules which will be signalled by visual indicator pulsing yellow Visual indicator glowing green the device communicates with the main controller directly Visual indicator pulsing yellow th...

Страница 21: ...us and al lows for assigning single device only main controller by default 2nd association group Roller Shutter is assigned to shutter po sition control UP DOWN uses Switch Multilevel command class 3r...

Страница 22: ...22 Configuration Switch Multilevel commands sent to association groups for pa rameter 151 set to 2 Click Hold Release Button 1 and 2 Start Stop Level Change 2nd group Set Level 3rd group...

Страница 23: ...in the Advanced Settings of the device Available parameters 11 LED frame colour when moving Description This parameter defines the LED colour when the motor is running Parameter size 1B Default value...

Страница 24: ...rameter allows reversing the operation of the buttons Parameter size 1B Default value 0 Available values 0 default 1st button UP 2nd button DOWN 1 reversed 1st button DOWN 2nd button UP 25 Outputs ori...

Страница 25: ...0x4X LED frame blinks blue 0x8X dis able LED frame 0xFX LED frame LAPD signal red white blue 31 Alarm configuration 2nd slot Description This parameter determines to which alarm frames and how the de...

Страница 26: ...ame blinks green 0x4X LED frame blinks blue 0x8X dis able LED frame 0xFX LED frame LAPD signal red white blue 33 Alarm configuration 4th slot Description This parameter determines to which alarm frame...

Страница 27: ...tion Status 3B Event State Parameters 4B LSB action 0x00 no action 0xX1 open 0xX2 close 0x0X no action on LED frame 0x1X LED frame blinks red 0x2X LED frame blinks green 0x4X LED frame blinks blue 0x8...

Страница 28: ...ption This parameter determines which actions result in sending scene IDs assigned to them Values can be combined e g 1 2 3 means that scenes for single and double click are sent Enabling scenes for t...

Страница 29: ...lue parameter 61 Parameter size 2B Default value 3600 1h Available values 0 periodic reports disabled 30 32400 30s 9h 1s step time interval 65 Energy reports on change Description This parameter defin...

Страница 30: ...parameter allows adjusting operation ac cording to the connected device Parameter size 1B Default value 1 Available values 1 roller blind with positioning 2 Venetian blind with positioning 5 roller b...

Страница 31: ...e limit switch is reached 2 slats return to previously set position in case of the main controller operation momen tary switch operation when the limit switch is reached or after receiving the Switch...

Страница 32: ...set manually Parameter size 4B Default value 6000 60 seconds Available values 1 65535 0 01 655 35 seconds 157 Time of down movement Description This parameter determines the time needed for roller bli...

Страница 33: ...and Class Version Secure COMMAND_CLASS_ZWAVEPLUS_INFO 0x5E V2 COMMAND_CLASS_SWITCH_MULTILEVEL 0x26 V4 YES COMMAND_CLASS_ASSOCIATION 0x85 V2 YES COMMAND_CLASS_MULTI_CHANNEL_ASSOCIA TION 0x8E V3 YES COM...

Страница 34: ...ES COMMAND_CLASS_MULTI_CHANNEL_ASSOCIA TION 0x8E V3 YES COMMAND_CLASS_ASSOCIATION_GRP_INFO 0x59 V2 YES COMMAND_CLASS_SECURITY 0x98 V1 COMMAND_CLASS_SECURITY_2 0x9F V1 COMMAND_CLASS_SUPERVISION 0x6C V1...

Страница 35: ...t Local 0 Unprotected The device is not protected and may be operated normally via the user interface Buttons connect ed with outputs Local 2 No operation possible button can not change relay state an...

Страница 36: ...le Cover Plate FG Wx PP 0004 Parts required for GIRA System 55 only with non metalised out er surface Standard 55 E2 Event Event Clear covers Required FIBARO parts Name Symbol Walli Roller Shutter Uni...

Страница 37: ...her brands and product names referred to herein are trademarks of their respective holders Declaration of conformity Hereby Fibar Group S A declares that the device is in com pliance with the essentia...