Fiat FSC-30 Скачать руководство пользователя страница 4

DOC NO. 81009

4 OF 9

Rev A 10/03

Water Inlet

Refer to figure 2 for the following:

1.

 

Connect tee to the hot or cold water line. Install copper pipe to the tee. If an in-line filter were to be
installed on the water line to the generator, (which is suggested), it would be preferable to install the
tee on the cold water line.

2.

 

Install a brass shut-off valve on the water inlet line in an accessible area prior to the brass union and
recommended in-line water filter.

3.

 

Before making the last connection to the 3/8” water inlet line coming to the unit, flush the water line
into a five-gallon pail to remove ant silt or other materials that maybe in the line.

4.

 

Make the final connection and turn on water. All Fiat generators are equipped with an automatic water
fill system. The water will stop after unit is filled.

IMPORTANT: MAXIMUM WATER PRESSURE IS 70 P.S.I.

Steamhead Installation

1.

 

Drill a 1-1/4” diameter hole in 

the shower stall

 wall (8.5” in from the face of the unit and 17” from the

floor) or 

Tub/Stall

 wall (10” from the face of unit and 21.5” from the floor) for the steam outlet line.

ƒ

 

CAUTION: The steamhead is hot! And should not be located near a seat or bench!

2.

 

Install the black rubber grommet (provided) into the 1-1/4” hole for the steam outlet. Connect ½” F.I.P.
copper pipe or copper tubing and ½” brass union onto the steam outlet. Run a ½” copper pipe from the
union to the 1-1/4” hole in wall. Install a ½” M.I.P. on the end of the ½” pipe for the steamhead.

3.

 

Attach the steamhead and escutcheon to the copper pipe. 

CAUTION: Do not obstruct the steam line

with any shut-off valves, plugs or caps. ALL generators are designed to build NO PRESSURE.

ƒ

 

The steam line can run up, down, or horizontal; 

but cannot run down and then up

. If it

does, a steam trap will be produced at the low point blocking the flow of steam. Insulate the
steam outlet piping if the piping run exceeds 10 feet or is exposed to cold areas. 

NOTE: Use

steam rated insulation.

Figure 2

Figure 2a

Drip Box

Содержание FSC-30

Страница 1: ...For Machines of Manufacture post May 2002 Owners Manual Thank You Fiat Products LTD 255 Hutchings Street Winnipeg Manitoba R2X 2R4 Canada TEL 204 633 6122 Service info 800 585 7832 If you are a tradesperson installing this unit please leave this owners manual with the owner when you finish the installation ...

Страница 2: ... control Steamhead escutcheon Steam generator Rubber Grommet Drip Box Materials Needed Copper or Brass nipple sizes and quantities per instructions 3 8 brass or copper union brass or copper union Copper tubing or pipe Brass or copper tee connection plug Tools Needed Pipe Wrench Tubing cutter Flaring tool if flared fittings are used Pipe thread cap Adjustable wrench Screwdrivers Phillips Regular So...

Страница 3: ...line to the generator flush water line into a five gallon pail to remove any slit or other materials that may be in the line An in line water filter is recommended 9 Make sure water is turned on to the unit before testing or operating the unit 10 Warranty on the acrylic shell may be nullified if the drip box is not mounted on the steam head and used in conjunction with the steam option Caution If ...

Страница 4: ...tion 1 Drill a 1 1 4 diameter hole in the shower stall wall 8 5 in from the face of the unit and 17 from the floor or Tub Stall wall 10 from the face of unit and 21 5 from the floor for the steam outlet line CAUTION The steamhead is hot And should not be located near a seat or bench 2 Install the black rubber grommet provided into the 1 1 4 hole for the steam outlet Connect F I P copper pipe or co...

Страница 5: ...enerator Model Wire Gauge Breaker Size KW FSC 30 10 20 3 0 FSC 50 10 30 5 0 FSC 70 8 40 7 0 FSC 90 8 50 9 0 1 Turn off all electricity to the working area at the main breaker panel 2 Connect 208 240 volt AC electrical lines to wires labeled 1 2 on generator See figure 3 NOTE All electrical wiring must be done per local electrical codes Figure 3 ...

Страница 6: ...nnect the other end of the lead wire to the generator BEFORE turning power on to the generator 4 Turn on both water and power to the generator 5 Test the touch pad to ensure it is properly connected If any technical problems arise call toll free 800 585 7832 6 THESE STEPS MUST BE TAKEN OR YOUR WARRANTY WILL BE VOID Coat the entire control back with supplied waterproof silicone Completely seal the ...

Страница 7: ...his steam bath 1 Starting your steam bath Press STEAM button to activate your steam bath session 60 minute LED will light up see figure 5 2 Changing session time Press STEAM button again and repeat until your desired time session lights up see figure 6 3 Pause feature Press STEAM button and hold until LED time light flashes Release Light will flash while system is in pause mode Press STEAM button ...

Страница 8: ... digital control has a unique diagnostic feature If there is a malfunction within the unit it will alert you The 15 minute light flashes when the control button is stuck see figure 9 The 60 minute light flashes when the low water sensor is activated see figure 10 To reset the control when an error occurs turn the main power to the generator off and then back on If the problem persists contact the ...

Страница 9: ...ity breaker off 3 Remove drain plug to remove water from tank to floor drain or bucket 4 Reopen the water supply to flush unit for a few minutes 5 Turn Water supply off 6 Reinstall drain plug 7 Turn water supply on wait until unit is full 8 Inspect for any leakage around drain plug 9 Turn Electricity on run a 30 minute cycle for test For other maintenance questions Please Call 1 800 585 STEAM 7832...

Отзывы: