Requirements for proper installation
1.
Use copper or brass fittings only.
(NEVER USE GALVANIZED FITTINGS)
2.
The water inlet and steam outlet need brass unions for easy removal.
3.
The Generator must be upright, accessible, and on a level surface.
4.
Unit may be installed up to 25 feet away from shower area.
5.
Do not
use ABS PVC or any plastic material for the steam line.
6.
Do not
plumb a trap in the steam line.
7.
Pitch steam line back towards generator and avoid perfectly level plumbed lines.
8.
Before connecting water line to the generator, flush water line into a five-gallon pail to remove
any slit or other materials that may be in the line. An in-line water filter is recommended.
9.
Make sure water is turned on to the unit before testing or operating the unit.
10.
Warranty on the acrylic shell may be nullified if the drip box is not mounted on the steam head
and used in conjunction with the steam option.
Caution:
If the unit is run without water, serious damage may occur! This possible damage is not
covered under the limited warranty.
Note: Failure to follow specific installation instructions will cause the warranty to be void.
Various options for the location of your Fiat steam Generator.
UNIT & SUPPLY LINES MUST BE PROTECTED FROM FREEZING!!!