Display
F1X5_RS
Data: 13/01/16
file: F1X5_RS_ing.doc
Pag 5/12
PROGRAMMING
In the scheme below you can find the programming digits associated to their peculiar functions:
PGM
To start the programming
To increase the number, which is being modified.
To select the constant to modify
To proceed from one numeral to the following one.
To leave the constant programming sections
RESET/ENTER
To confirm the data you have just inserted
Press
PGM
To start the programming section: the number
“000” ,
whose first numeral on the
right flashes, is displayed. At this point you are requested to insert the number
273
in the following way:
press
to increase the flashing number
Press
to select the flashing number
After introducing
273
pls. confirm by means of
RESET
/
ENTER
. For some seconds you will read the word
“Set1” followed by its own value.
N.B.: If you input a false password, the instrument will immediately leave the programming phase.
Press
RESET
/
ENTER
and modify the constant value by means of the digits
Press
RESET
/
ENTER
again to confirm your choice
Press
to start working with other constants or
Press
to leave the programming section
The constants, which have to be programmed, and can be run over by the digit are the following ones:
Threshold for relay 1, not used in version without relay
Threshold for relay 1, not used in version without relay
The display shows a value after 1 encoder revolution
Impulse number after one encoder revolution
Decimal numbers
Preset quote
Zero setting
Input selection (encoder or proximity sensor)
Debounce of the count inputs
Start of the output relay , not used in version without relay
Thresholds for the relays, not used in version without relay
# %
Baud rate serial port comunication
%%.
Address device
Constants
Threshold for Relay 1
Not used in version without relay.
Threshold for Relay 2
Not used in version without relay.