![FIAL 2310 AL Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/fial/2310-al/2310-al_manual_2285756023.webp)
MODEL 2310 AL MCS-11 REMOTE ENCODER
FIAL INCORPORATED
FC2310_AL-20040506
19
Figure 12. RCDI PAGE
The RCDI pane is used to specify which RCDI scanner will operate the 16 relays. A checkbox for
each relay allows ON/OFF or Momentary operation. This is discussed in detail below.
CHOOSE RCDI SCANNER FOR THE RELAY OUTPUTS:
You are allowed to select a RCDI
scanner from
A
through
F
. All 16 control points in the 2310 AL will be controlled via the scanner
which you select.
CHECK IF MOMENTARY:
The control points default to the ON/OFF mode. An MCS-11
ON
command will
close
the targeted relay. An MCS-11
OFF
command will
open
the targeted relay.
If the checkbox next to the control point number is checked, then that point will be configured for
momentary mode. In momentary mode, an ON command causes the relay to be closed for 200
milliseconds, then released. An OFF command is ignored. When momentary points are actuated,
the MCS-11 RCDI status reflects the ON condition to the master. The amount of time that a
momentary point's status is reflected as ON must be set in the configuration program. See the
item
Number Of Seconds To Show Momentary Assertion
under the General tab on page 15.