15 / 18
To Define Manual Call Acceptance
You can define this call acceptance scenario by setting the programmed ring/signal
counter *11xx* (3) to the value “99”. Incoming calls will then be acoustically
1)
and
optically signaled, and only accepted when the on/off button is pressed.
Example:
#1234#
Receive programming authorization.
*
1199
*
Set call counter to the value “99”, to shut off automatic call
acceptance.
1)
With a programmed ring volume of *1600*, the speaker is muted when the call is
being signaled.
Problem handling:
Unexpected disabling of any communications (call/call reception)
You start a call or receive a call and the communication is more or less immediately
disabled.
This problem may occur, if the IntellyCom or set of your interlocutor is installed in a
noisy environment. If those ambient noises hit the busy tone schema of the
IntellyCom, it considers the connection as disabled by the interlocutor and switches
off.
You can switch off the operation mode „disable in case of busy tone“ by setting the
option *101x* (0) to the value 1. Please note, that in a noisy environment the
operation mode "Disable in case of continuous silence *13xx* (28 s)" will also be
affected. To guarantee an automatic disabling of the IntellyCom, the maximum call
duration, which in the delivery condition is adjusted to infinite *12xx* (0 infinite), should
be limited to a convenient value.
Example:
#1234#
Obtain the programming authorization.
*101
1
*
Set option "disable in case of busy tone" to the value 1, to deactivate
the disabling in case of identified busy tone.
*12
05
*
Determine the maximum call duration to e.g. 5 min., to guarantee that
the IntellyCom switches off automatically.
Unexpected muting at the beginning of outgoing communications (call)
You start a call; your interlocutor answers the call and does not hear you at the
beginning.
This problem may occur, of the IntellyCom does not understand the message of your
interlocutor and continues the supervision of the calling phase with muted microphone
and flashing loop current display.