Go to fetco.com for the latest versions of all information
Page 12
P169 NOVEMBER 2018
ERROR CODES
Error codes must be corrected!
Diagnose the cause and repair.
To clear: reboot the brewer by
toggling power switch:”OFF/ON“
# Error
Description
2
Internal Error (software)
Improper startup or shutdown
3
CRC Error
Internal data memory malfunction
50
Shorted temperature probe
Probe failure
51
Open temperature probe or circuit
Probe failure, bad connection
100
Initial fill error when
>
10 minutes fill time Water supply rate too low-(Toggle Off/On)
101
Refill error-if not filled in
>
5 minutes time Water supply rate too low or is off
102
Unwanted fill error
Possible leak in tank or water connection
201
Heater open (temp.rise<2° in 10 minutes) Bad heater, open one-shot fuse
201
Heater short (temp.rise>5° with heat “off”) Bad Thermostat or heating element
255
Keyboard Error-pressed>2 minutes
Touch pad or connection bad
9.11
FIRMWARE VERSION, Used for service
Displays on bottom of touchscreen when powered up