Fetco HWD-2102 Скачать руководство пользователя страница 2

Go to fetco.com for the latest version of all information                                     

 

P119  User Guide HWD-2102      REVISED MARCH 2020

 

 

 

FETCO HWD-2102 push-button commercial hot water dispensers with portion control 

 

 

 

 

Dimensions & Utility Connections HWD_2102

 

DRAWING1201.00005.00 

 

 

 

Electrical Configurations  

Configuration 

Code 

Heater 

Configuration  Voltage  Phase  Wires 

Electrical Connection 

KW 

Amp 

Draw 

Flow Rate* 

Per hour 

 H210210 

1 X 1.4 KW 

100-120  single  2+G 

NEMA 5-15P 

1.5 

12.5  3.6 Gal/13.6 liters 

 H210220 

1 X 2.1 KW 

100-120  single  2+G 

NEMA 5-20P 

2.2 

18.3  5.4Gal/20.4 liters 

 H210230 

1 X 3.2 KW 

200-240  single  2+G 

NEMA 6-15P 

3.3 

13.8  8.2Gal/31.0 liters 

 H210240 

1 X 3.2 KW 

200-240  single  2+G 

cord only without plug 

3.3 

13.8  8.2Gal/31.0 liters 

  *Flow rate based on 55°F/13°C water mains supply and dispensing From (“READY” Light ON) 

  Portion Control: factory calibrated to dispense portion of 200ml/6.8oz—at  timer setting: 5sec 

Portion control is user selectable: 40-1200cc/1.4-40.6fl.oz. Portion size is controlled by setting dispense timer. 

Actual portions and temperatures shown are estimated and are influenced by mains flow rate and temperature 

 

Power Plug Configurations  

 

Please see wiring diagrams located in back pages for installation notes. 

 

  Specifications and Requirements

 

Capacities & Measurements  

Brewer 

Height 

Width 

Depth 

Empty 

Weight 

Filled 

Weight 

Hot Water Tank 

Capacity 

Shipping 

Weight  Shipping Dimensions 

HWD-2102 

19

 inch 

483 mm 

8inch 

203 mm 

16

 inch 

410 mm 

19 lb 

8.6kg 

36 lb 

16.3kg 

1.8 gal 

6.9 liter 

25lb 

11.3kg 

26 X 13 X 17in 

660 X 330 X 432mm 

  Water Requirements 
Water Connection: Inlet:

  

3/8 inch male flare fitting

 

Mains Pressure

:          

20-75 psig (138-0.517 mPa)  (45psi/0.310 mPa preferred)

   

Minimum Flow Rate

:       1½ 

gpm  

 

All commercial hot water dispensers to be supplied with filtered water from mains

 

  The following are the factory settings—and range of variables that are adjustable: 

 

Portion Control: 

Delivery volume: factory set at 16 seconds=630ml/21.3oz 

(Portion control is user selectable from minimum to maximum single dispense is 40ml/1.4 ounces to 

1200ml/40.5 ounces by 1 sec to 30seconds timer adjustment)  

  Temperature Control

:

 

Water temperature is factory set at maximum—88°C/190°F 

(Temperature is user selectable 87-96°C/189° to 205°F) 

  Hot Water Tank Temperature

, as set by factory: 

96°C/205°F inside water tank (at sea level)

 

  Electrical Requirements: See electrical configuration charts (above)

.

 

           

 

 

 

                  W 

           

 

 

 

 
                                

NEMA PLUG CONFIGURATION 

 

 

 

 

   NEMA 5-15P     NEMA 5-20P   NEMA 6-15P 

           

 

 

 

 

 
                                

 

Содержание HWD-2102

Страница 1: ...000 Fax 847 719 3001 Email sales fetco com techsupport fetco com PATENTS WWW fetco com patents P11919 REVISED March 2020 User s Guide Hot Water Dispenser HWD_2102 With Portion Control Domestic and Export Version Table of Contents Operator And User Sections Operating Instructions 3 Operating Principles 4 Adjusting Temperature and Dispense Portion 5 Error Messages 7 Cleaning Maintenance 8 Profession...

Страница 2: ...Power Plug Configurations Please see wiring diagrams located in back pages for installation notes Specifications and Requirements Capacities Measurements Brewer Height Width Depth Empty Weight Filled Weight Hot Water Tank Capacity Shipping Weight Shipping Dimensions HWD 2102 19 inch 483 mm 8inch 203 mm 16 inch 410 mm 19 lb 8 6kg 36 lb 16 3kg 1 8 gal 6 9 liter 25lb 11 3kg 26 X 13 X 17in 660 X 330 X...

Страница 3: ...d Multiple dispenses are possible when the UNLOCK DISPENSE light pad is steady and red colored Reactivate next dispense portion by retouching pad Finger must be on pad to dispense To dispense with PORTION CONTROL Touch and Hold 1 Press and hold UNLOCK DISPENSE pad for 3 seconds to unlock and activate dispensing system Border of UNLOCK DISPENSE pad will rapidly strobe signaling activation 2 Remove ...

Страница 4: ...ing ON activation Hot water is drawn from the faucet the fill valve cycles on and off to replenish the hot water tank When dispensing water at a rate that exceeds the unit s capacity to heat the ready light will go off to show that the selected preset temperature is not available Always observe the READY lamp When the green READY lamp is lit proper dispense temperature is enabled When heating or r...

Страница 5: ...8 C 172 F and increments in two degree Celsius units Add two degrees for each dial position numerical value in degrees Celsius C to 78 base to a maximum of 96 C 205 F Unit is factory set at 96 C 205 F Lower Dials Marked S1 S2 Set dispense volume The two lower dials control the hot water volume to be delivered by setting the dispense time in seconds The timer dials are additive and control flow for...

Страница 6: ...Settings in table may vary and are given for the conditions below Mains 0 34MPa 50PSI and Flow Rate 5 7lpm 1 gpm at 55 F 13 C Correction for altitude table Portion size setting Flow is 40ml per second and is proportional to mains pressure The two timer dials are additive and control flow for 1 to 30 seconds Dispense volume at 1 30 seconds is approximately 40 1200ml 1 3 40 6 fluid ounces Portion ti...

Страница 7: ...ith suggested setting for the operator at higher elevations BLINK BLINK ON Heater open If the heater is on and Tank temperature is not increasing according to software logic and the tank temperature 92C HEATER OPEN This means that the power board or that the heater control triac is sending power to the heater but the heating element is faulty or damaged OPEN circuit Fault is with the damaged heati...

Страница 8: ...fore turning on power 5 No user serviceable parts refer to qualified service technician for repair and adjustments 6 Dangerous high voltage and high temperatures inside 7 Unplug machine before disassembly or changing settings 8 Operation requirements and maintenance for commercial cooking appliances differ from household appliances 9 Operators must be trained for this equipment and must understand...

Страница 9: ...al service connection is compatible with the specifications on the equipment serial number label Make sure the electrical service will match the current draw of the equipment 11 Access the terminal block for electrical connection in the front of the unit by following the illustration above 12 A fused disconnect switch or circuit breaker on the incoming power line must be conveniently located near ...

Страница 10: ...ice area is restricted to persons having safety hygiene knowledge and practical experience of the coffee brewer This appliance must be installed in locations where it can be overseen by trained personnel 2 For proper operation this appliance must be installed indoors where the temperature is between 10 C 50 F to 35 C 95 F Drain and remove al liquid from equipment and lines if exposed to freezing t...

Страница 11: ...0 WASHER 6 SCREW INTL TOOTH LOCKWASHER 6 4 1084 00010 00 NUT HEX 6 32 UNDERSIZED ZINC PLATED 7 1 1051 00016 00 BOARD TRIAC DRIVE WITH RC FILTER 8 1 1023 00166 00 FITTING COLD WATER INLET GROMMET DESIGN 9 3 1024 00050 00 GROMMET SILICONE 11 4mm ID 10 1 1023 00167 00 FITTING BREW GROMMET DESIGN 11 2 1024 00053 00 LEVEL AND TEMP PROBE GROMMET 12 1 1112 00002 00 PROBE WELDMENT WATER LEVEL 2 25 LG 13 1...

Страница 12: ...Go to fetco com for the latest version of all information P119 User Guide HWD 2102 REVISED MARCH 2020 12 ...

Страница 13: ...1029 00017 00 FAUCET SILICONE HWD 2100 22 1 1023 00153 00 TOP COVER HWD 2102 23 1 1102 00250 00 ASSEMBLY FRONT PANEL MEMBRANE SWITCH HWD 2102 24 1 1023 00154 00 BOTTOM BASE HWD 2102 25 1 1023 00152 00 FRONT PANEL BOTTOM HWD 2102 26 4 1023 00136 00 LEG HWD 2100 27 1 1102 00156 00 DRIP TRAY ASSEMBLY HWD 2100 28 1 1024 00041 00 PUSH IN GROMMET 1 4 ID 7 16 PANEL HOLE 29 10 1082 00058 00 SCREW 8 32 X 5...

Страница 14: ...Go to fetco com for the latest version of all information P119 User Guide HWD 2102 REVISED MARCH 2020 14 Wiring Diagram ...