Commissioning

Note

 Commissioning only by qualified personnel.
 When incompressible media (e.g. neutral water) are used, switching the valve

causes pressure surges in the tubing system. Prior to commissioning, check
the compatibility of the devices in the system to avoid damaging them. If
necessary, adjust your application parameters.

 Observe the information on the rating plate.
 Start up the solenoid valve only when it is completely assembled and installed.
 Check the connection points for leaks.
 Prior to commissioning, check for compliance with the operating conditions and

the permissible limit values (

è

 Technical data).

8

Operation

 Observe the operating conditions.
 Always observe the permissible limit values.

Warning

Danger of burning on hot surfaces.
The surface temperature of the solenoid valve can exceed 75 °C.
 Do not touch the solenoid valve.

9

Dismantling

Warning

Danger of injury due to hot media under pressure.
The media in the piping system and the solenoid valve can be hot and can be
under pressure.
 Allow the solenoid valve and pipelines to cool and depressurise them.

Note

The solenoid valve may be dismantled only by qualified personnel.

1. Depressurise the pipeline.
2. Switch off the voltage.
3. Completely drain the pipeline and valve.

– Allow the solenoid valve and pipeline to cool off.
– Make sure that no one is in front of the outlet opening.
– Catch escaping media in a suitable container.

4. Remove the solenoid valve from the pipeline (unplug the electrical plug con­

nector, detach the mounting bracket and unscrew the fittings).

10

Changing the solenoid coil

The solenoid coil can be changed for repairs.

Warning

Danger of injury from hot surfaces.
The surface temperature of the solenoid valve can exceed 75 °C.
 Let the solenoid valve cool off.

Dismantling:

1. Switch off the voltage.
2. Disconnect the electrical plug connector.
3. Undo the knurled nut and remove the solenoid coil from the armature guiding

tube.

Mounting:

1. Push the O-ring and solenoid coil over the armature guiding tube.
2. Secure the solenoid coil with the O-ring and knurled nut.

– Torque for tightening the knurled nut: finger-tight (about 1...1.5 Nm).

11

Service and maintenance

 Check the solenoid valve for leakage at least every 6 months.
 Check the functioning of the solenoid valve at least every 6 months.
 Regularly clean the outside of the valve with a soft cloth. The permissible 

cleaning agent is soap suds.

12

Eliminating malfunctions

Malfunction

Possible cause

Remedy

Solenoid  valve
not closing

Solenoid valve is defective.

 Replace the solenoid valve.

Flow direction is incorrect

 Install the solenoid valve in accord­

ance with the flow arrow

Nominal voltage is still applied

 Check electrical connection.

Differential pressure too low

 Make sure the specified minimum 

differential pressure is supplied.

Solenoid valve
does not open

Solenoid coil or solenoid valve is
defective.

 Replace the solenoid coil.
 Replace the solenoid valve.

Nominal voltage interrupted or
not sufficient

  Check voltage.

Fig. 4

13

Technical data

General

VZWP-L-M22C-...

Valve function

2/2-way, closed, monostable

Design

Pilot­actuated piston poppet valve

Actuation type

Electrical

Mounting position

Coil preferably on top

Sealing principle

Soft

Medium

Compressed air in accordance with ISO8573­1:2010 [7:4:4]
Inert gases, Neutral fluids

1)

Direction of flow

Non-reversible

Viscosity

[mm

2

/s]

š

 22

Grade of filtration

[μm]

40

Temperature of medium

[°C]

–10...+80

Ambient temperature

[°C]

–10...+35

Protection class

IP65 as per DIN EN 60529

Degree of contamination

3 as per IEC 60664-1

Attachment type

In-line installation

Materials information, housing

Cast brass

Materials information for seals

NBR, FPM

1)

Other media on request

Fig. 5

Electrical data

VZWP-...1-...

VZWP-...2A-...

VZWP-...3A-...

Nominal voltage

– DC voltage
– AC voltage (50...60 Hz)

[V DC]
[V AC]

24 (±10%)


110 (±10%)


230 (±10%)

Rated output

[W]
[VA]

6.8


7.5


10.5

Surge resistance

[kV]

2.5

4.0

Duty cycle

100% (continuous duty)

Electrical connection

Device plug per DIN EN 175301-803, format A

Connecting cable

– Cable cross-section

[mm

2

]

0.75…1.5

– Cable diameter

[mm]

5…9

– Cable entry thread

M20x1.5

Fig. 6

Port size

[˝]

¼

y

½

¾

1

Pipe thread per DIN ISO 228
Pipe thread per ANSI B 1.20.1

G

¼

N

¼

G

Å

N

Å

G

½

N

½

G

¾

N

¾

G1
N1

Differential pressure

[bar]

0.5

Nominal size DN

[mm]

13

25

Standard nominal flow rate

[l/min]

1600

2100

2650

8750

12250

Flow factor K

v

[m

3

/h]

1.5

2.0

2.5

8.2

11.5

Operating pressure

[bar]

0,5…40

Overload pressure

[bar]

45

Switching times for gaseous media

1)

– On

[ms]

100

130

– Off

[ms]

250

300

Tightening torques

– Pipe connection

[Nm]

35

60

105

200

350

– Mounting of solenoid coil

[Nm]

2

Weight

[g]

600

575

550

1500

1400

1)

Depending on the viscosity, longer switching times with fluid media

Fig. 7

Отзывы: