VPPM−...−DE/E N
Festo VPPM−... 0810b English
33
Pneumatic installation
S
Remove the fastening elements from the supply ports.
S
Connect the tubing of the supply port
6
and the air port
7
(see Fig.1).
Screw on a silencer to the exhaust port
8
.
Electrical installation
Warning
S
Use only power units which guarantee reliable electrical isolation of the
operating voltage as per IEC/DIN EN 60204−1. Observe also the general
requirements for PELV power circuits as per IEC/DIN EN 60204−1.
Please note
Long signal cables reduce the immunity to interference.
S
Make sure that the signal cable is not longer than 10 m.
S
Check which valve variant you have using the rating plate:
Designation on the rating plate
VPPM−...−V1...
VPPM−...−A4...
Designation
Voltage variant
Current variant
Electrical setpoint value
0 ... 10 V DC
4 ... 20 mA
Fig.10
S
Check the use of the following options on the VPPM−...:
Measurement of the actual value of voltage or current.
S
Make sure that the cable installation is
neither squashed, bent nor stretched:
S
Use the pre−assembled plug socket with
cable from Festo (see chapter 9 Acces
sories"). This ensures that the specified
protection class IP65 and EMC are ful
filled.
S
If a screened cable is used, earth the insulation at the cable end which is
farther away from the VPPM.
Fig.11