Property
Specification/value
Height without plug
[mm]
150
Length
[mm]
70
Operating medium
Operating medium
Compressed air to ISO 8573-1:2010 [6:4:4]
Note on the operating medi-
um
Lubricated operation not possible
Maximum particle size 5 µm
(use 5 µm filter)
Electrical data
Nominal operating voltage
[V DC]
24
Operating voltage range
[V DC]
21.6 … 26.4
Permissible residual ripple of
operating voltage
[%]
5
Maximum current consump-
tion
[A]
1.2 (momentary)
Operating and environmental conditions
Operating pressure
[bar]
4 … 8
Ambient temperature
[°C]
0 … 50
Storage temperature
[°C]
–20 … +70
Degree of protection
IP65 (fully installed)
CE marking (declaration of
conformity
è
In accordance with EU-EMC Directive
1)
KC marking
KC EMC
Resistance to vibration/shock resistance (to IEC 60068)
Note
Explanation of the severity levels (SG)
è
Tab. 7 Features of severity level (SL)
Vibration (part 2 - 6)
SG 2
Shock (part 2 – 27)
SG 2
Materials
Housing
Anodised wrought aluminium alloy
Screws
Galvanised steel
Seals
FPM, HNBR, NBR
Piston
Aluminium, ematal coated
Actuator
Steel, copper, HNBR
1) The component is intended for industrial use. Outside of industrial environments, e.g. in commercial and
mixed-residential areas, it may be necessary to take measures to suppress interference.
Tab. 6 Technical data
Features of severity level (SL)
Vibration load
Frequency range [Hz]
Acceleration [m/s
2
]
Deflection [mm]
SL1
SL2
SL1
SL2
SL1
SL2
2 … 8
2 … 8
–
–
±3.5
±3.5
8 … 27
8 … 27
10
10
–
–
27 … 58
27 … 60
–
–
±0.15
±0.35
58 … 160
60 … 160
20
50
–
–
160 … 200
160 … 200
10
10
–
–
Shock load
Acceleration [m/s
2
]
Duration [ms]
Shocks per direction
SL1
SL2
SL1
SL2
SL1
SL2
±150
±300
11
11
5
5
Continuous shock load
Acceleration [m/s
2
]
Duration [ms]
Shocks per direction
±150
6
1000
Tab. 7 Features of severity level (SL)