background image

Property

Specification/value

Height without plug

[mm]

150

Length

[mm]

70

Operating medium

Operating medium

Compressed air to ISO 8573-1:2010 [6:4:4]

Note on the operating medi-
um

Lubricated operation not possible
Maximum particle size 5 µm
(use 5 µm filter)

Electrical data

Nominal operating voltage

[V DC]

24

Operating voltage range

[V DC]

21.6 … 26.4

Permissible residual ripple of
operating voltage

[%]

5

Maximum current consump-
tion

[A]

1.2 (momentary)

Operating and environmental conditions

Operating pressure

[bar]

4 … 8

Ambient temperature

[°C]

0 … 50

Storage temperature

[°C]

–20 … +70

Degree of protection

IP65 (fully installed)

CE marking (declaration of
conformity

è

 www.festo.com/sp)

In accordance with EU-EMC Directive

1)

KC marking

KC EMC

Resistance to vibration/shock resistance (to IEC 60068)

Note

Explanation of the severity levels (SG)

è

 Tab. 7 Features of severity level (SL)

Vibration (part 2 - 6)

SG 2

Shock (part 2 – 27)

SG 2

Materials

Housing

Anodised wrought aluminium alloy

Screws

Galvanised steel

Seals

FPM, HNBR, NBR

Piston

Aluminium, ematal coated

Actuator

Steel, copper, HNBR

1) The component is intended for industrial use. Outside of industrial environments, e.g. in commercial and

mixed-residential areas, it may be necessary to take measures to suppress interference.

Tab. 6 Technical data

Features of severity level (SL)

Vibration load

Frequency range [Hz]

Acceleration [m/s

2

]

Deflection [mm]

SL1

SL2

SL1

SL2

SL1

SL2

2 … 8

2 … 8

±3.5

±3.5

8 … 27

8 … 27

10

10

27 … 58

27 … 60

±0.15

±0.35

58 … 160

60 … 160

20

50

160 … 200

160 … 200

10

10

Shock load

Acceleration [m/s

2

]

Duration [ms]

Shocks per direction

SL1

SL2

SL1

SL2

SL1

SL2

±150

±300

11

11

5

5

Continuous shock load

Acceleration [m/s

2

]

Duration [ms]

Shocks per direction

±150

6

1000

Tab. 7 Features of severity level (SL)