background image

8099702

VAEM-L1-S-...-AP

Electrical interface

8099702
2019-06
[8099704]

Instructions | Operat-
ing

Содержание VAEM-L1-S Series

Страница 1: ...8099702 VAEM L1 S AP Electrical interface 8099702 2019 06 8099704 Instructions Operat ing ...

Страница 2: ...Translation of the original instructions 2 Festo VAEM L1 S AP 2019 06 ...

Страница 3: ... Training of qualified personnel 5 3 Additional information 5 4 Service 5 5 Product overview 5 5 1 Function 5 5 2 Configuration 6 5 2 1 Product design 6 5 2 2 Connecting elements 6 6 Assembly 7 7 Installation 8 8 Commissioning 8 9 Parameterisation 8 10 Diagnostics and fault clearance 9 10 1 Diagnostic messages 9 10 2 LED displays 11 11 Disposal 12 12 Technical data 13 Table of contents ...

Страница 4: ...s 1 2 Product version This document refers to the following product versions Product Version VAEM L1 S 12 AP Valve terminal connection VAEM L1 S 12 AP revision 1 or later VAEM L1 S 24 AP Valve terminal connection VAEM L1 S 24 AP revision 1 or later Tab 2 Product version The product version can be identified from the product labelling There may be an updated version of this document for these or la...

Страница 5: ...ide of industrial environments e g in commercial and residential mixed use areas it may be necessary to take measures to suppress radio interference Use only in combination with modules and components that are permissible for the respective product variant è www festo com catalogue Only use the product if it is in perfect technical condition 2 3 Training of qualified personnel Installation commiss...

Страница 6: ...for voltage forwarding XD2 6 Connection for power supply XD1 7 LED load voltage PL 8 LED module diagnostics MD Fig 1 Product design 5 2 2 Connecting elements Connection for power supply XD1 Plug M8 4 pin A coded Signal 1 24 V DC logic supply PS 2 0 V DC load supply PL 3 0 V DC logic supply PS 4 24 V DC load supply PL Tab 4 Connection for power supply Product overview 6 Festo VAEM L1 S AP 2019 06 ...

Страница 7: ... for system communication Connection for system communication XF20 Socket M8 4 pin D coded Signal 1 RX Received data 2 TX Transmitted data 3 RX Received data 4 TX Transmitted data Tab 7 Connection for system communication 6 Assembly NOTICE Damage to internal electronics Damage to components and malfunctions due to incorrect handling Observe the handling specifications for electrostatically sensiti...

Страница 8: ... of the LED displays of the module after error free commissioning Information on troubleshooting in the event of incorrect behaviour è Instruction manual for automation system CPX AP è 10 Diagnostics and fault clearance 9 Parameterisation Various parameters are available for reading out information about the modules in an automation sys tem CPX AP and adapting the modules to the application situat...

Страница 9: ...lue of logic supply PS mV 1 UINT16 ro 20088 Current measured value of load supply PL mV 1 UINT16 ro 20093 Hardware version 1 UINT8 ro 1 ro read only rw read write Tab 9 Parameter 10 Diagnostics and fault clearance 10 1 Diagnostic messages ID hex dec Message Description Undervoltage of the logic supply PS 24 V DC was detec ted Remedy Check logic supply PS 02 01 0016 33619990 Undervoltage in logic s...

Страница 10: ... can be a deliberate shutdown by the emergency stop Remedy Check if the emergency stop was activ ated Check load supply PL 02 01 0106 33620230 Switch off load supply PL 24 V DC Diagnost ic status Information Overvoltage in the load supply PL 24 V DC Remedy Check load supply PL 02 01 013F 33620287 Overvoltage in the load supply PL 24 V DC Diagnost ic status Error Tab 10 Diagnostic messages Diagnost...

Страница 11: ... Degree of severity Warning e g parameterisation error Take appropriate remedial action e g check parameterisation Illuminated red Module diagnostics active Degree of severity Error e g undervoltage in load supply PL Take appropriate remedial action e g check load supply PL LED flashes red quickly Module ramp up not yet completed System communication not yet initial ised Flashes quickly green Modu...

Страница 12: ...vailable Check load supply PL Flashes red Load supply PL outside the tolerance range Check load supply PL Tab 12 LED load supply PL 11 Disposal ENVIRONMENT Send the packaging and product for environmentally sound recycling in accordance with the current regulations è www festo com sp Disposal 12 Festo VAEM L1 S AP 2019 06 ...

Страница 13: ...12 Technical data Technical data 13 Festo VAEM L1 S AP 2019 06 ...

Страница 14: ...ge temperature C 20 60 Storage time years 2 max Humidity non condensing 5 95 Number of valves 12 max 24 max Number of solenoid coils 24 max 48 max Assigned address space inputs outputs bytes 3 6 Module code hex dec 0x200B 8203d 0x200C 8204d Module identification VAEM L1 S 12 AP VAEM L1 S 24 AP Degree of protection in accordance with EN 60529 IP65 IP67 if assembled cables connected and connections ...

Страница 15: ...neral technical data VAEM L1 S 12 AP VAEM L1 S 24 AP Electromagnetic com patibility See declaration of conformity è www festo com Tab 13 General technical data Technical data 15 Festo VAEM L1 S AP 2019 06 ...

Страница 16: ... sumption at nominal operating voltage 24 V from PL mA 15 22 Diagnostic message undervoltage in load supply PL V 21 6 Diagnostic message overvoltage in load supply PL V 26 4 Capacitive load at load supply PL 24 V PL to 0 V PL nF Typ 35 24 V PL to FE nF Typ 35 0 V PL to FE nF Typ 20 Electrical isolation Between PS and PL Yes Between the channels No Short circuit protection Per channel Electronic Be...

Страница 17: ......

Страница 18: ... others without express authorization is prohibited Offenders will be liable for damages All rights reserved in the event that a patent utility model or design patent is registered Copyright Festo AG Co KG 73734 Esslingen Ruiter Straße 82 Germany 49 711 347 0 Phone Internet www festo com ...

Отзывы: