background image

Assembly instructions (original: de) 
8021977 
1211NH 

 

 

 

†‡ 

 

Pressure/intermediate zone  
supply module, End plate 
VABF-P5-...A3/VABE-P5-C 

Festo AG & Co. KG 

 
P.O. box 
73726 Esslingen, Germany 
+49 711 347-0 
www.festo.com 

 

 

 

 

 

 

1.

 

Parts list 

 
 
 
 

18262d_1 

 

Compressed-air supply plate 
VABF-P5-P3A3-... 

1

  Plate 

2

  Seal 

3

  M5x12 screw 

(1x) 
(1x) 
(4x) 

 
 
 

18262d_3 

 

End plate 
VABE-P5-C 

1

  Plate 

2

  Seal 

3

  M5x12 screw 

(1x) 
(1x) 
(4x) 

 
 
 
 
 

18262d_2 

 

Intermediate zone  
supply module 
VABF-P5-P1A3-... 

1

  Plate 

2

  O-ring 

3

  M6x20 screw 

4

  Slot nut 

(1x) 
(1x) 
(2x) 
(2x) 

 
 

 

1826

2d_6 

Not included in scope  
of delivery: 

 

5

  Mounting rail 

(1x) 

 

IPM-PN-08-40x80-AL 

 

 

As intended: 

 

The compressed-air supply plate serves as a lateral supply port and seal 
of the mounting rail 

 

The end plate serves as seal for the mounting rail 

 

The intermediate zone supply module serves as frontal, additional supply 
port of the mounting rail. 

 

 

Note 

 

Select additional accessories from the catalogue 
(e.g. mounting plate VAME-P5-MK). 

For mounting of the mounting plates (

 relevant assembly instructions). 

2.

 

Preassembly (for attachment of an intermediate zone supply module) 

 

 

Note 

To ensure an optimal compressed air supply when an intermediate zone 
supply module is used. 

 

Observe that: 

 

The intermediate zone supply module 

1

 should be set as closely as  

possible to the centre 

 

Several intermediate zone supply modules 

1

 must be distributed evenly. 

The required distance from the mounting plates VAME-P5-MK 
(

 relevant assembly instructions). 

 

Mark the position for the hole (A). 

 

Drill the corresponding hole (A) 

@

 12 mm. 

 

Deburr the hole (A). 

 

On each of both sides, cut a thread (M5, depth 

 10 mm) into the  

4 holes (B) 

 

Remove all shavings from the mounting rail 

5

 
 

3.

 

Mounting 

3a.

 

Mounting of the intermediate zone supply module 

 

18262d_7 

 

 

Note 

To avoid mounting problems 
during the assembly  
sequence: 

 

Remove the slot nuts 

4

 

from the centre of the 
mounting rail 

5

 

(

 centre hole (A)). 

 

 

Push the slot nuts 

4

 into the mounting rail 

5

 

18262d_8 

 

 

Place the O-ring 

2

 in the 

depression in plate 

1

 

Position the plate 

1

 on the 

mounting rail 

5

 until the 

hole (A) and thread (C) are 
aligned. 

 

Tighten the screws 

3

Comply with the permissible 
tightening torque. 
 

 

3b.

 

Mounting of the compressed-air supply plate or end plate 

 

18262d_4 

 

 

Place the seal 

2

 in the 

opening (D). 
Observe thereby the  
mounting position 
(

 magnifying glasses). 

 

Fasten the plates 

1

 on the 

desired side to the mount-
ing rail 

5

 with screws 

3

Observe the permissible 
tightening torque. 

 

 

 
 

18262d_5 

 

 

2 Nm 

_

 10 % 

2 Nm 

_

 10 % 

2 Nm 

_

 10 % 

3  1 