background image

1

User instructions

Control panel type SPC200-MMI-... is designed for commission-
ing, programming, diagnosing and operating the Smart
Positioning Controller SPC200. It can be fitted directly onto the
SPC200 when the power supply is switched off.

Detailed information on the control panel as well as on com-
missioning and programming the SPC200 with the control panel
can be found in the User Manual P.BE-SPC200-.... .

CAUTION:
Pay strict attention to the following instructions shown
therein:
– safety guidelines
– specifications for the use of each module and component.

WARNING
If the control panel is plugged into or disconnected from the
SPC200 while the power supply is switched on, actuators
may be activated unintentionally and both the SPC200 and
the control panel may be damaged.
Before undertaking installation and/or maintenance work,
switch off the following sources of power in the sequence
specified:
1. the compressed air supply
2. the load voltage and operating voltage supplies for
    the SPC200.

SPC200-MMI-1

9804NH

9

Содержание SPC200-MMI-1

Страница 1: ...Kurzbeschreibung Bedienfeld Typ SPC200 MMI 1 Brief description Control panel type SPC200 MMI 1 9804NH...

Страница 2: ...Deutsch 3 English 9 Festo AG Co D 73726 Esslingen 1998 SPC200 MMI 1 9804NH 2...

Страница 3: ...Bediener Handbuch P BE SPC200 VORSICHT Beachten Sie unbedingt die dort aufgef hrten Sicherheitstechnischen Hinweise den bestimmungsgem en Gebrauch der jeweiligen Baugruppen und Module WARNUNG Aktoren...

Страница 4: ...nen men gef hrt aufgerufen werden k nnen 1 2 3 Anzeige LCD Display mit 2 x 16 Zeichen Folientastatur Schnittstelle zum SPC200 auf der R ckseite Das Bedienfeld bietet alle n tigen Funktionen zur Inbetr...

Страница 5: ...nungsversorgung des SPC200 Das Bedienfeld Typ SPC200 MMI l t sich direkt auf die Diagnosebaugruppe Typ SPC200 MMI DIAG des SPC200 auf stecken Gehen Sie bei der Montage wie folgt vor 1 Druckluftversorg...

Страница 6: ...parung f r Raststifte Buchse f r Bedienfeld X3 Gehen Sie bei der Demontage wie folgt vor 1 Druckluftversorgung abschalten 2 Betriebsspannung und Lastversorgung des SPC200 abschal ten 3 Bedienfeld von...

Страница 7: ...etriebstemperatur Lagerung Transport 5 50 C 20 70 C Relative Luftfeuchtigkeit 95 nicht kondensierend Schutzart nach DIN 40050 Bedienfeld aufgesteckt IP 20 Schwingung und Schock Schwingung Schock gepr...

Страница 8: ...SPC200 MMI 1 8 9804NH...

Страница 9: ...CAUTION Pay strict attention to the following instructions shown therein safety guidelines specifications for the use of each module and component WARNING If the control panel is plugged into or disc...

Страница 10: ...can be accessed via menus 1 2 3 Display LCD display with 2 x 16 characters Touch sensitive keyboard Interface to SPC200 on the rear The control panel offers all the functions necessary for com mission...

Страница 11: ...tage and operating voltage supplies for the SPC200 Control panel type SPC200 MMI can be plugged directly onto the diagnostic module type SPC200 MMI DIAG of the SPC200 Proceed with the fitting as follo...

Страница 12: ...g pins Socket for control panel X3 Proceed as follows when dismantling 1 Switch off the compressed air supply 2 Switch off the operating voltage and the load voltage for the SPC200 3 Carefully remove...

Страница 13: ...ure range operation storage transport 5 50 C 20 70 C Relative humidity 95 non condensing Protection class as per DIN 40050 Control panel plugged in IP 20 Oscillation and shock oscillation shock Tested...

Страница 14: ...SPC200 MMI 1 14 9804NH...

Отзывы: