Festo SOPA Скачать руководство пользователя страница 8

IO-Link

Protocol version

Device V1.1

Device V1.1

Smart sensor profile

Function classes

Switching signal channel (SSC)
Process data variable (PDV)
Identification
Diagnostics
Teach channel

Communication mode

COM2 (38.4 kbaud)

SIO mode support

yes

Port class

A

Process data width IN

2 bytes

Process data content IN

2 bit SSC (distance monitoring)
1 bit SSC (supply pressure monitoring)
10 bit PDV (distance)

Service data IN

14 bit (supply pressure)

Cycle time

³

 3 ms

Device ID

SOPA-…-PNLK-VB

0xC0 (192)

SOPA-…-PNLK-A

0xC1 (193)

IODD, IO-Link device description

è

  www.festo.com/sp

Tab. 21: IO-Link

12.2

Diagrams

Response times for different tube lengths

Fig. 17: Typical response time t as a function of distance x after switching on the

instrument air (measuring nozzle: 2 mm)

Fig. 18: Typical response time t as a function of distance x after switching off the

exhaust air (measuring nozzle: 2 mm)

Displays for different tube lengths

Fig. 19: Influence of the tube length on the dimensionless display value

(measuring nozzle 2 mm)

Repetition accuracy of the switching point

Fig. 20: Repetition accuracy of the switching point [±µm] as a function of the

switching point distance x (measuring nozzle: 2 mm)

12.3

Hole patterns

Fig. 21: Hole patterns

Содержание SOPA

Страница 1: ...tegory code NRNT2 NRNT8 File number E253738 Considered standards UL 508 CSA22 2 No 14 UL mark Tab 2 UL CSA certification information This device is intended to be used with a Class 2 power source or C...

Страница 2: ...max flash SHOW mode active 7 segment display shows the minimum or maximum value InC Marked segments light and Option flashes EDIT mode active Special menu opens 7 segment display shows the set option...

Страница 3: ...Pmax IO Link SP1 SPmin SP2 SPmax no TEACH mode Tab 7 Window comparator with switching point SP and hysteresis HY Hysteresis Hysteresis serves to suppress switching signals in the event of fluctuations...

Страница 4: ...204 1 for PELV circuits Only use voltage sources that ensure a reliable electric separation from the mains network in accordance with IEC 60204 1 EN 60204 1 1 Use signal lines that are shorter than 30...

Страница 5: ...onds RUN mode is active Option 2 teaching in the switching point for OutA 1 Establish the desired switching distance between the object and the meas uring nozzle 2 Press and hold the A pushbutton 3 Al...

Страница 6: ...nger displayed 4 If the delay SUP P in the display is too great reduce the time by turning the control valve towards HIGH 9 Maintenance and Care 1 Switch off the energy sources operating voltage compr...

Страница 7: ...resent Electronic Rated operating voltage V DC 24 Operating voltage V DC 15 0 30 0 20 0 30 0 22 8 26 4 No load supply current mA 50 10 Reverse polarity protection for all electrical connections Electr...

Страница 8: ...1 193 IODD IO Link device description www festo com sp Tab 21 IO Link 12 2 Diagrams Response times for different tube lengths Fig 17 Typical response time t as a function of distance x after switching...

Отзывы: