Festo SOPA Скачать руководство пользователя страница 1

SOPA

Air gap sensor

Festo SE & Co. KG

Ruiter Straße 82

73734 Esslingen

Deutschland

+49 711 347-0

 

www.festo.com

Operating instructions
8163013

2021-08d

[8163015]

Translation of the original instructions

© 2021 all rights reserved to Festo SE & Co. KG

1

About this document

1.1

Purpose of the document

This document describes the use of the above-mentioned product. Certain
aspects of use are described in other documents and must be observed 

è

 1.2

Applicable documents.
1.2

Applicable documents

All available documents for the product 

è

  www.festo.com/sp.

Document

Table of contents

Description of air gap sensor SOPA

Functional description, installation, commis-
sioning, servicing, description of the IO-Link
parameters, technical data

Tab. 1: Applicable documents

2

Safety

2.1

General safety instructions

Only use the product in its original condition without unauthorised modifica-
tions.

Only use the product if it is in perfect technical condition.

Only use media in accordance with the specifications 

è

 Technical data.

Observe labelling on the product.

Note that changes to the switching status (EDIT mode) become effective imme-
diately.

2.2

Intended Use

The air gap sensor SOPA is intended for distance monitoring in a range of
20 … 200 µm. The distance measurement is performed using a non-contact pneu-
matic measuring process. This enables it to be used in harsh ambient conditions.
2.3

Training of qualified personnel

Work on the product may only be carried out by qualified personnel who can
evaluate the work and detect dangers. The qualified personnel have skills and
experience in dealing with electrical (open-loop) control technology.
2.4

UL/CSA certification

In combination with the UL inspection mark on the product, the information in this
section must also be observed in order to comply with the certification conditions
of Underwriters Laboratories Inc. (UL) for USA and Canada.

UL/CSA certification information

Product category code

NRNT2/NRNT8

File number

E253738

Considered standards

UL 508
CSA22.2 No. 14

UL mark

Tab. 2: UL/CSA certification information
This device is intended to be used with a Class 2 power source or Class 2 trans-
former in accordance with UL1310 or UL1585.
As an alternative a LV/C (Limited Voltage/Current) power source with one of the
following properties can be used:

This device shall be used with a suitable isolating source such that the max-
imum open circuit voltage potential available to the product is not more than
30 V DC and the current is limited to a value not exceeding 8 amperes meas-
ured after 1 minute of operation.

This device shall be used with a suitable isolating source in conjunction with
a fuse in accordance with UL248. The fuse shall be rated max. 3.3 A and
be installed in the 30 V DC power supply to the device in order to limit the
available current.

3

Additional information

Contact the regional Festo contact if you have technical problems

è

  www.festo.com.

Accessories and spare parts 

è

  www.festo.com/catalogue.

Device description file IODD 

è

  www.festo.com/sp.

4

Product overview

4.1

Structure

4.1.1

Product design

1

2

3

4

5

6

7

8

9

10

11

12

13

14

13

3

15

16

17

18

19

20

Fig. 1: Product design

1 Supply port for supply pressure
2 Sensor module (max. 4 modules

permitted in combination with
control module)

3 Plug for electrical connection
4 Display
5 Edit button
6 B pushbutton
7 A pushbutton
8 Label holder
9 Pneumatic port for measuring

nozzle (outlet)

10 Supply port for operating pres-

sure

11 Vent screw (width across flats 14)
12 Mounting slides
13 Threaded sleeve (M4)
14 Blanking plug (M7)
15 Control module (optional)
16 Manual LED (green) – ready

indication for manual override
(SOPA-C..-H only)

17 Clean pushbutton (blow-out air)

(SOPA-C..-H only)

18 Status LED (yellow) – clean (blow-

out air)

19 Sense pushbutton (measuring air)

(SOPA-C..-H only)

20 Status LED (yellow) – sense

(measuring air)

4.1.2

Display components

1

2

3

4

5

6

Fig. 2: LCD display

1

Display of binary output OutA

2

Display of binary output OutB

3

Display of binary output OutC

4

4-digit alphanumeric display

5

Toolbar for functions

6

Bar graph

Содержание SOPA

Страница 1: ...tegory code NRNT2 NRNT8 File number E253738 Considered standards UL 508 CSA22 2 No 14 UL mark Tab 2 UL CSA certification information This device is intended to be used with a Class 2 power source or C...

Страница 2: ...max flash SHOW mode active 7 segment display shows the minimum or maximum value InC Marked segments light and Option flashes EDIT mode active Special menu opens 7 segment display shows the set option...

Страница 3: ...Pmax IO Link SP1 SPmin SP2 SPmax no TEACH mode Tab 7 Window comparator with switching point SP and hysteresis HY Hysteresis Hysteresis serves to suppress switching signals in the event of fluctuations...

Страница 4: ...204 1 for PELV circuits Only use voltage sources that ensure a reliable electric separation from the mains network in accordance with IEC 60204 1 EN 60204 1 1 Use signal lines that are shorter than 30...

Страница 5: ...onds RUN mode is active Option 2 teaching in the switching point for OutA 1 Establish the desired switching distance between the object and the meas uring nozzle 2 Press and hold the A pushbutton 3 Al...

Страница 6: ...nger displayed 4 If the delay SUP P in the display is too great reduce the time by turning the control valve towards HIGH 9 Maintenance and Care 1 Switch off the energy sources operating voltage compr...

Страница 7: ...resent Electronic Rated operating voltage V DC 24 Operating voltage V DC 15 0 30 0 20 0 30 0 22 8 26 4 No load supply current mA 50 10 Reverse polarity protection for all electrical connections Electr...

Страница 8: ...1 193 IODD IO Link device description www festo com sp Tab 21 IO Link 12 2 Diagrams Response times for different tube lengths Fig 17 Typical response time t as a function of distance x after switching...

Отзывы: