Translation of the original instructions

© 2020 all rights reserved to Festo SE & Co. KG

1

About this document

1.1

Purpose of the Document

This document describes the use of the above-mentioned product. Certain
aspects of use are described in other documents and must be observed

è

 1.2 Applicable Documents.

1.2

Applicable Documents

All available documents for the product 

è

 www.festo.com/pk.

Document

Contents

Description of air gap sensor SOPA

Functional description, installation, commission-
ing, maintenance, description of the IO-Link
parameters, technical data

IO-Link IODD

Device Description File

Tab. 1 Applicable Documents

2

Safety

2.1

General Safety Instructions

Only use the product in original status without unauthorised modifications.

Only use the product if it is in perfect technical condition.

Only use media in accordance with the specifications 

è

 Technical data.

Observe labelling on the product.

Note that changes to the switching status (EDIT mode) become effective
immediately.

2.2

Intended Use

The air gap sensor SOPA is intended for distance monitoring in a range of
20 … 200 μm. The distance measurement is performed using a non-contact pneu-
matic measuring process. This enables it to be used in harsh ambient conditions.

2.3

Training of qualified personnel

Installation, commissioning, maintenance and disassembly should only be con-
ducted by qualified personnel.

2.4

UL/CSA Certification

In combination with the UL inspection mark on the product, the information in this
section must also be observed in order to comply with the certification conditions
of Underwriters Laboratories Inc. (UL) for USA and Canada.

UL/CSA Certification Information

Product category code

NRNT2 (USA)
NRNT8 (Canada)

File number

E253738

Considered standards

UL 508, 17th edition
C22.2 No. 14-2005

UL mark

Tab. 2 UL/CSA Certification Information

This device is intended to be used with a Class 2 power source or Class 2 trans-
former in accordance with UL1310 or UL1585.
As an alternative a LV/C (Limited Voltage/Current) power source with one of the
following properties can be used:

This device shall be used with a suitable isolating source such that the max-
imum open circuit voltage potential available to the product is not more than
30 V DC and the current is limited to a value not exceeding 8 amperes meas-
ured after 1 minute of operation.

This device shall be used with a suitable isolating source in conjunction with
a fuse in accordance with UL248. The fuse shall be rated max. 3.3 A and be
installed in the 30 V DC power supply to the device in order to limit the avail-
able current.

3

Further information

Accessories 

è

 www.festo.com/catalogue.

Spare parts 

è

 www.festo.com/spareparts.

4

Service

Contact your regional Festo contact person if you have technical questions

è

 www.festo.com.

5

Product overview

5.1

Configuration

5.1.1

Product Design

1 Supply port for supply pressure

2 Sensor module (max. 4 modules

permitted in combination with con-
trol module)

3 Plug for the electrical connection

4 Display

5 Edit button

6 B pushbutton

7 A pushbutton

8 Label holder

9 Pneumatic connection for measur-

ing nozzle (output)

10 Supply port for operating pressure

11 Vent screw (width across flats 14)

12 Fastening slides

13 Threaded sleeve (M4)

14 Blanking plug (M7)

15 Control module (optional)

16 Manual LED (green) – Ready indic-

ation for manual override (only
SOPA-C..-H)

17 Pushbutton - Clean (exhaust air)

(only SOPA-C..- H)

18 Status LED (yellow) – Clean

(exhaust air)

19 Pushbutton - Sense (measuring

air) (only SOPA-C..- H)

20 Status LED (yellow) – Sense

(instrument air)

Fig. 1 Product Design

5.1.2

Display Components

1 Display of binary output OutA

2 Display of binary output OutB

3 Display of binary output OutC

4 4-digit alphanumeric display

5 Toolbar for functions

6 Bar graph

Fig. 2 LCD display

8118603

SOPA

Air gap sensor

8118603
2019-12c
[8118605]

Instructions | Operating

Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0

www.festo.com

Содержание SOPA Series

Страница 1: ...be used with a Class 2 power source or Class 2 trans former in accordance with UL1310 or UL1585 As an alternative a LV C Limited Voltage Current power source with one of the following properties can b...

Страница 2: ...ft and right and C illuminate min or max flash SHOW mode active 7 segment display shows the minimum or maximum value InC Marked segments illuminate and Option flashes EDIT mode active Special menu ope...

Страница 3: ...NC normally closed In Supply pressure Switching function 2 switching points SPmin SPmax IO Link SP1 SPmin SP2 SPmax No TEACH mode Tab 7 Window Comparator Hysteresis Hysteresis serves to suppress switc...

Страница 4: ...supply use only PELV circuits in accordance with IEC 60204 1 EN 60204 1 Protective Extra Low Voltage PELV Observe the general requirements of IEC 60204 1 EN60204 1 for PELV cir cuits Only use voltage...

Страница 5: ...the desired switching distance between the object and the measur ing nozzle 2 Press A pushbutton and keep it pressed 3 Additionally press the Edit button OutA and TeachIn flash The value is adopted a...

Страница 6: ...s 11 Malfunctions 11 1 Fault Clearance Fault description Cause Remedy Supply voltage not applied or permitted operating voltage not present Switch on the supply voltage observe the voltage range Elect...

Страница 7: ...able Switching function OutA Threshold value comparator with variable hysteresis OutB Threshold value comparator with variable hysteresis OutC Window Comparator Switching element function N C contact...

Страница 8: ...35 mm to DIN EN 60068 part 2 6 Tab 31 Immissions Emissions IO Link Protocol version Device V1 1 Device V1 1 Smart sensor profile Function classes Switching signal channel SSC Process data variable PDV...