SFAM
8
Festo – SFAM – 2017-09c English
A (Out A). The combination of air consumption measurement (Out A) and flow rate measurement
(Out B) is possible. The flow rate value is passed on via the analogue output (Out C).
2.1
Operating statuses
INFO mode
EDIT mode
TEACH mode
RECORDER mode
SHOW mode
Fig. 2
SFAM operating statuses
RUN mode
In the RUN mode, the following are displayed:
–
the measurement values for the flow rate (in l/min or scfm)
–
the measurement values for air consumption (in m³, scf or l) and
–
the signal statuses of the switching outputs Out A, Out B (set, not set).
INFO mode
In INFO mode, when air consumption measurement is active, the display of input variables (flow rate,
air consumption) can be switched quickly in the display. The display can be switched by pressing the
Apushbutton or B pushbutton.
SHOW mode
In SHOW mode, the current settings for the switching outputs Out A and Out B, as well as the
min/maxvalues for the flow rate or air consumption measurement, are displayed. The min/max values
can be reset.
EDIT mode
In EDIT mode, the settings for the flow sensor (switching outputs, standard condition, physical unit,
etc.) can be made or changed.
TEACH mode
In TEACH mode, the switching points can be taught.