SFAM
20
Festo – SFAM – 2017-09c English
5.5
EDIT mode
Fig. 6
EDIT mode
5.5.1
Start EDIT mode
In the EDIT mode, you can configure settings for the switching output Out A, the switching output Out B
and the special menu [Spec].
Warning
Manipulation of signal statuses may cause serious personal injury, depending on the
functioning of the machine/system.
Note that if the switching status of the outputs is modified in EDIT mode, the new
status will be effective immediately.
1. Press the Edit button.
The EDIT mode is active and [Out A] flashes or, if there is an active security lock, [Lock] flashes.
2. Press the A/B pushbuttons until the chosen security code is set.
3. Press the Edit button.
The EDIT mode is active and [Out A] flashes.
4. Press the A/B pushbutton to switch between the setting modes for Out A, Out B and the special
menu.