Festo P.BE−K−SBO−M 0511NH English
18
Status LEDs
Status
Description
A
Readiness to
operate
lights up
green
System is ready to operate.
lights up red
Initialization is running
flashes red
Fault
off
Undefined status, e.g. operating
voltage not applied
B
Ethernet
traffic
flashes green
Ethernet data traffic (Traffic)
traffic
off
No Ethernet data traffic (Traffic)
C
Recording
lights up red
Lights up at each recording for at
least 250 ms
lights up
yellow
Lights up for 250 ms when trigger
signal is applied
D
Recording
status
flashes red
Recording data available in the
memory
flashes yellow
System waits for trigger signal
(ready for recording)