OVEM-…-LK
56
Festo – OVEM-…-LK – 1602NH English
4
Parameter description
Note
Related device description file (IODD)
è
www.festo.com/sp.
For detailed information on the IO-Link specification and for the Smart Sensor Profil
è
www.io-link.com.
4.1
General instructions, IO-Link
Characteristic
Specification
Protocol version
Device V1.1
Profile
Smart Sensor Profile
Function classes
è
Communication mode
COM2 (38.4 kBaud)
Port class
A
Process data width IN
2 bytes (
è
Process data content IN
2 bit BDC (pressure monitoring),
14 bit PDV (pressure measurement value)
Process data width OUT
1 byte (
è
Process data content OUT
1 bit (vacuum ON/OFF), 1 bit (ejector pulse ON/OFF)
Block parameterisation
Supported
Data memory required
0.5 KB
Minimum cycle time
3.5 ms
SIO mode support
Yes
Tab. 4
General instructions (general IO-Link specification)
4.2
Identification parameters
Identification direct parameters (Identification Direct Parameters)
Index
Name
Value
Description
Inform
0x07
VendorID1 (MSB)
0x01
Manufacturer identification
R
0x08
VendorID2 (LSB)
0x4D
0x09
DeviceID1 (MSB)
0x00
Device identification
0x0A
DeviceID2
0x00
0x0B
DeviceID3 (LSB)
3C
Device variant OVEM-...-H-...-OE
3D
Device variant OVEM-...-L-...-OE
3E
Device variant OVEM-...-H-...-CE
3F
Device variant OVEM-...-L-...-CE
1)
R = read
Tab. 5
Identification direct parameters (Identification Direct Parameters)