OVEM-…-LK
Festo – OVEM-…-LK – 1602NH English
57
Identification device parameters (Identification Device Parameters)
Index
Sub-
index
Name
Value
Description
Inform
0x0010
0
Vendor Name
Festo AG & Co. KG
Manufacturer name
R
0x0011
0
Vendor Text
http://www.festo.com Includes additional information
0x0012
0
Product Name
e.g. OVEM-05-H-B-QO-
CE-N-LK
Complete order code of the
product
0x0013
0
Product ID
e.g. OVEM-H-CE
Device variant/type designation
0x0014
0
Product Text
Vacuum generator
Device characteristic
0x0015
0
Serial Number
XXXXXXXXXXX
Product key
0x0016
0
Hardware
Revision
e.g.
8037693REV00101
Part number and revision status
of the product
0x0017
0
Firmware
Revision
e.g. V00.23.03.23
Firmware version of the device
0x0018
0
Application
SpecificTag
***
Application-specific marking,
can serve as functional identific
ation.
R/W
FR
DS
1)
R = read, R/W = read and write,
FR = factory reset (Factory Reset), DS = data storage (Data Storage) possible
Tab. 6
Identification device parameters (Identification Device Parameters)
4.3
Process data (Process data)
Process input data (Process data IN)
Bit
15 (MSB)
2 (LSB)
1
0
Process Data Variable (PDV)
BDC3
Pressure Value
Out B
Out A (Air-save) / Out A
1)
R = read
2)
Assignment of the BDC is dependent on the parameter Air-saving function: Air-save ON = BDC1, Air-save OFF = BDC2
3)
Current pressure value (pressure value) standardised and scaled to 14 bit. Formula: p2 = pressure value*(1000 mbar/16383)
Tab. 7
Process input data (Process data IN)
Process output data (Process data OUT)
Bit
15 (MSB)
2 (LSB)
1
0
Reserved
Reserved
Drop
Vacuum
1)
W = write, no data storage (Data Storage)
2)
Values: BCS2 = 0: ejector pulse solenoid valve not switched, BCS2 = 1: ejector pulse solenoid valve switched
3)
Values: BCS1 = 0: vacuum solenoid valve not switched, BCS1 = 1: vacuum solenoid valve switched
Tab. 8
Process output data (Process data OUT)
Содержание OVEM LK Series