background image

MS9-SV

-10V24P

-V24

-V110

-V230

Nominal operating voltage

[ V DC]

24

24

[V AC]

110

230

Electrical connection

Plug,
M12x1,
4-pin

Plug, rectangular design, in accord-
ance with EN 175301-803, shape A

Coil characteristics

24 V DC,
2.7 W

24 V DC,
8.4 W

110 V AC
50/60 Hz:
pick-up
power
14.5/12 VA
holding ca-
pacity
10.5/7.6 VA

230 V AC
50/60 Hz:
pick-up
power
14.5/12 VA
holding ca-
pacity
10.5/7.6 VA

Permissible voltage fluctu-
ation

[%]

10

Sound pressure level

[dB(A)]

93

Protection class in accordance with
IEC 60529

IP65

Housing material information

Die-cast aluminium

Cover material information

Wrought aluminium alloy

Lower cover material information

PA

Seals material information

NBR

Product weight

[g]

3200

Fig. 11 General data

13.3 Venting flow rate
Flow rate qn dependent on the number of revolutions n of the main throttle screw
(HD)

Range up to 5 revolutions

p1: 3 bar
p1: 6 bar
p1: 10 bar
p1: 14 bar

Fig. 12 Flow diagram

13.4 Pressure switching point

With the main throttle (MT) located in the cover, a slower pressure build-up of
output pressure p2 is achieved. If the output pressure p2 has reached the switch-
through pressure, the valve opens and the complete operating pressure p1 builds
up at the output. The pressure switching point can be set by turning the adjusting
screw for the pressure switching point (PSP).

1

2

1

PSP maximum

2

PSP minimum

Fig. 13 Pressure switching point

Example:

At an operating pressure p1 = 6 bar, the pressure switching point can be set in a

range of 1.8 … 5.5 bar.

13.5 Venting time

The following table shows the venting time in normal operation (N) with silencer
U-1-B ,

11 Accessories, at various volumes and operating pressures.

Normal opera-
tion N

Operating
pressure
4 bar

Operating
pressure
6 bar

Operating
pressure
10 bar

Operating
pressure
16 bar

Venting time [s]

Venting time [s]

Venting time [s]

Venting time [s]

at
1.0 bar

at
0.5 bar

at
1.0 bar

at
0.5 bar

at
1.0 bar

at
0.5 bar

at
1.0 bar

at
0.5 bar

Volume [l]

10

0.53

0.62

0.65

0.75

0.8

0.9

0.93

1.03

20

0.69

0.89

0.9

1.08

1.13

1.31

1.37

1.56

40

1.17

1.55

1.62

2.02

2.02

2.44

2.56

3.02

150

3.48

4.87

4.66

6.1

6.49

8.11

8.33

10.09

Fig. 14 Venting time

Содержание MS9-SV-10V24P

Страница 1: ... in accordance with EN 175301 10V24P 24 V DC M12 in accordance with IEC 61076 2 101 V110 110 V AC connection arrangement in accordance with EN 175301 V230 230 V AC connection arrangement in accordance with EN 175301 Options S Silencer Tamper protection MH Cover only manual override MO MK Cover adjusting screws pressure switching point PSP and main throttle MT manual override MO Fig 2 Overview of v...

Страница 2: ...omponents Fig 4 Standards 3 5 Service Please consult your local Festo repair service if you have any technical problems 4 Mounting and installation 4 1 Mechanical Note Information about mounting of module connectors sub bases and mounting brackets can be found in the operating instructions enclosed with the relevant accessories Place the MS9 SV C as close as possible to the location of use Place t...

Страница 3: ...ig 9 Troubleshooting 13 Technical data 13 1 Safety related characteristics MS9 SV 10V24P V24 V110 V230 Safety function Venting Performance Level PL Venting up to category 1 PL c Max pos test pulse at logic 0 µs 3800 3200 Max neg test pulse at logic 1 µs 4900 2800 Venting time s 13 5 Venting time CE marking see declaration of conformity To EU Low Voltage Dir ective Fig 10 Safety related characteris...

Страница 4: ...tle MT located in the cover a slower pressure build up of output pressure p2 is achieved If the output pressure p2 has reached the switch through pressure the valve opens and the complete operating pressure p1 builds up at the output The pressure switching point can be set by turning the adjusting screw for the pressure switching point PSP 1 2 1 PSP maximum 2 PSP minimum Fig 13 Pressure switching ...

Отзывы: