Pick&Place station
© Festo Didactic 8034663
39
10.2
Mounting the profile plate and the control console
1
Profile plate
2
Hammer head nut, M6-32 (4 ea.)
3
Trolley
4
Socket head screw, M6x10 (4 ea.)
5
Sheet metal screw, 3.5x9 (2 ea.)
6
Control console
10.3
Cable connections
1.
PLC board to station
If the SysLink 19" system plug
module is used: connect socket A to
the SysLink socket on the
C interface using a SysLink cable or
the SysLink socket at the station’s
digital I/O terminal.
2.
PLC board to control console
If the SysLink 19" system plug
module is used: connect socket B to
the SysLink socket on the control
console using a SysLink cable.
3.
PLC board to power supply unit
Insert the 4 mm safety plug into the
socket on the power supply unit.
4.
PC to PLC
Connect your PC to the PLC via a
programming cable.