Operating and environmental conditions
The valves can be used at temperatures down to -5 °C. In order to prevent the condensate
and humidity from freezing, we recommend installing a dryer with which condensate and
humidity can be removed.
Ambient conditions
Permitted temperature range
Long-term storage
[°C]
-20 … +40
Operation
[°C]
-5 … +60
Medium
[°C]
-5 … +60
Relative air humidity at 40 °C
90 %
– IP65/IP67/IP69K in accordance with
IEC 60529
– NEMA6 in accordance with NEMA 250
Corrosion protection
Vibration/shock resistance
è
Assembly instructions
PWIS criterium
PWIS-free
1)
Requirement: valve terminal completely mounted, plug connector inserted or provided with protective cap. Observe that connec
ted devices might only satisfy a lower degree of protection, a smaller temperature range, etc.
2)
Corrosion resistance class 4 in accordance with Festo standard 940070-2: Components
subject to particularly high corrosion stress.
Externally visible parts with primarily functional surface requirements which are in direct contact with the surrounding industrial
environment or media such as solvents and cleaning agents.
Tab. A.4
Technical data: Ambient conditions
Valve terminal with multi-pin connection:
The maximum number of manifold sub-bases that can be configured equals the num
ber of addresses available (dependent on plug type, see section 2.3)
Valve terminal with I-Port interface/IO-Link:
Per valve position, one or two solenoid coils and within the valve terminal a maximum
of 32 solenoid coils can be controlled via I-Port/IO-Link.