Pin
Address
Valve
position no.
Coil
Description
1
2
0
1
0
14
12
3 valve positions equipped with:
– Valves with two solenoid coils each
– Black electronics modules
3
4
2
3
1
14
12
5
6
4
5
2
14
12
—
—
—
—
3
—
—
Supply plate:
– Blue electronics module (does not occupy
an address)
7
8
6
7
4
14
12
Valve position equipped with:
– Valve with two solenoid coils
– Black electronics module
9
8
5
14
Valve position equipped with:
– Valve with one solenoid coil
– Grey electronics module
10
11
9
10
6
14
—
Valve position equipped with:
– Valve with one solenoid coil
– Black electronics module
– Address 10 is assigned, but is not required
by the valve.
12
13
11
12
7
—
—
Valve position equipped with:
– Cover plate (valve position without valve)
– Black electronics module
– Addresses 11 and 12 are assigned.
25
0 V/24 V
Connect 0 V with positive-switching control signals,
24 V with negative-switching control signals. Mixed
operation is not permissible!
Tab. 3.6
Addressing example
Содержание MPAC-VI